Chapter 4 Communications Control
4-22
4
Read Commands
Item
Command
Data
Description
Format
Measurement
Value Read
RMD
-
-9500000 to
+9500000
-950.0000 to
+950.0000[mm]
FORMAT
2
Read Received
Light Intensity
RID
-
+00000 to
+04095
+00000 to +04095
+00000
Alarm OFF
Alarm status
ROA
-
+00001
Measurement Alarm ON
+00000
OUT1 OFF
OUT1 Terminal
Read
RZA
-
+00001
OUT1 ON
+00000
OUT2 OFF
OUT2 Terminal
Read
RZB
-
+00001
OUT2 ON
+00000
OUT3 OFF
OUT3 Terminal
Read
RZC
-
+00001
OUT3 ON
FORMAT
1
Read Com
m
and
All Outputs
Read
RMB
-
-
Mesured value/Received
light intensity
/OUT1/OUT2/OUT3/AL
FORMAT
3
*1. The data section consists of 5 digits (zero suppress is omitted) indicated in
decimal.
Buffering Commands
Item
Command
Data
Description
Format
+00000
Continuous
Buffering Mode
RBD WBD
+00001
Trigger
Buffering Rate
RBR WBR
+00001 to
+65535
+00001 to +65535
Accumulated Amount
RBC WBC
+00001 to
+03000
+00001 to +03000
Trigger Point
RTP WTP
+00001 to
+03000
+00001 to +
accumulated amount
Trigger Delay
RTL WTL
+00001 to
+65536
+00000 to +65535
+00000
At timing input ON
+00001
At or higher than
threshold
+00002
Lower than threshold
+00003
At an alarm occurred
RTR WTR
+00004
At an alarm released
FORMAT
1
B
u
ff
eri
ng Com
m
and
Trigger
Conditions
Threshold
RBL WBL
-9500000 to
+9500000
-950.0000 to
+950.0000[mm]
FORMAT
2