Chapter 3 Function
3-7
3
(1) RUN mode
The measurement value will appear on the digital display in this mode.
The system will be set to this mode when the system is turned ON.
RS-422/485 write and read commands will be received while the system is in
this mode.
(2) Setting mode
Use this mode to make setting changes.
RS-422/485 write commands cannot be received while the system is in this
mode.
An error command indicating that the system is in setting mode will be
returned if a write command is received.
Refer to the next page for the transition of the screen while the system is in
setting mode.
(3) Zero set
The measurement value will be set to zero in this mode.
(4) Reset
The measured value kept on hold by the system in measurement mode will be
reset.
(5) Threshold a
The screen will change to the threshold-a setting screen.
(6) Threshold b
The screen will change to the threshold-b setting screen.
(7) Initialization
Initialization deletes all settings and returns them to the factory default settings.
Supplemental remarks
Setting changes in the control panel of the sensor head will be saved in the
internal memory.