Chapter 6 Specifications
6-18
6
Output Characteristics
●
Diffuse reflection type
*1 In the figure above, analog output setting is used as the initial setting.
Standard type
High-function
type
Measurement center
distance (D)
Measurement
method (R)
30-mm type
HL-G103-A-C5
HL-G103-S-J
30 mm
±4 mm
50-mm type
HL-G105-A-C5
HL-G105-S-J
50 mm
±10 mm
85-mm type
HL-G108-A-C5
HL-G108-S-J
85 mm
±20 mm
120-mm type HL-G112-A-C5
HL-G112-S-J
120 mm
±60 mm
250-mm type HL-G125-A-C5
HL-G125-S-J
250 mm
±150 mm
Measurement (R)
Measurement center distance (D)
Displacement
output
11 V
21.6 mA
10.5 V
20.8 mA
10 V
20 mA
5 V
12 mA
Distance (mm)
0 V
4 mA
3.2 mA
OFF
ON
ON
ON
Alarm output
OFF