Chapter 4 Explanation of Functions
4-4
4
Cl
a
s
s
Function
Details
Initial value
Memory
change*1
Ref.
page
H
ea
d
S
et
ti
ng
Calibration
Measurement
value A
Corrects the measurement
value to the measurement
object’s color, material,
surface condition.
Upper measurement limit
(positive number)
Correct
value a
Upper measurement limit
(positive number)
Measurement
value B
Lower measurement limit
(negative number)
Correct
value b
Lower measurement limit
(negative number)
Peak Recognition
Sensitivity
Sets the peak of the
received light waveform and
the recognition level.
100
Median Filter
Cut off sudden changes in
measurement values in order to
prevent variation in measurement.
OFF
O
U
T
S
e
tt
in
g
Output Selection
Selects whether measurement
is individually performed by
each sensor head or
performed by two sensor
heads with various calculation.
OUT1:A
OUT2:B
Transparent Object
Selects the measurement
surface from several surfaces
existed in the transparent object.
1
st
surface
Refractive
Index
calculation
Reflects the refractive index,
which is set at “Refractive Index”,
to the measurement result.
OFF
Refractive
Index
Sets the refractive index for
measuring transparent object.
1.000000
Zero Set
Forcibly sets the
measurement value to “0”.
OFF
Timing
Holds the measurement value
display of compact programmable
display and analog output.
OFF
X
Reset
Resets the measurement value.
OFF
X
Hold
Stops updating the
measurement value display.
OFF
X
Analysis Mode
Sets the analysis mode.
Normal
Filter Operation
Selects the moving average,
low-pass, or high-pass.
Moving average
Average Times
Sets the average number of
times of moving average.
512 times
Cutoff frequency
Sets the cutoff frequency of
the low-pass/high-pass filter.
100Hz
Operation Coefficient
Sets the operation coefficient
for the measurement value.
1.000000
Offset
Adds/subtracts the offset value
to/from the measurement value.
0.00000mm
Judgm
ent
Output
Upper Limit value Sets upper/lower limit value
for judging the measurement
value.
Upper measurement limit
(positive value)
Lower Limit Value
Lower measurement limit
(negative value)
Upper Limit Hys. Stabilizes the judgment
output for chattering.
0.1% of the meas. range
Lower Limit Hys.
0.1% of the meas. range
Analog
Scaling
Meas. Val A
Performs scaling the analog
voltage output to any
desired value.
Upper meas. limit
(positive val.)
Voltage a
+5[V]
Meas. Val B
Lower meas. limit
(positive val.)
Voltage b
-5[V]
*1 Memory Change
: Maximum 16 settings can be saved by performing memory change.
X
: Settings can not be changed by performing memory change.
Содержание HL-C2 Series
Страница 32: ...Preface 30 MEMO ...
Страница 50: ...Chapter 1 Prior to Use 1 18 1 MEMO ...
Страница 65: ...Chapter 3 Programmable Display Operation 3 5 3 MEMO ...
Страница 164: ...Chapter 4 Explanation of Functions 4 90 4 MEMO ...
Страница 191: ...6 1 6 6 Maintenance and Inspection 6 1 Maintenance 6 2 6 2 Inspection 6 2 ...
Страница 200: ...Chapter 7 Troubleshooting 7 8 7 MEMO ...
Страница 249: ...Chapter 8 Specifications 8 49 8 8 5 Characteristics Beam Diameter 10mm type Unit mm 30mm type Unit mm ...
Страница 250: ...Chapter 8 Specifications 8 50 8 50mm type Unit mm 85mm type Unit mm ...
Страница 252: ...Chapter 8 Specifications 8 52 8 8mm type Unit mm 15mm type Unit mm ...
Страница 254: ...Chapter 8 Specifications 8 54 8 85mm type HL C208 HL C208 MK Unit mm 110mm type HL C211 HL C211 MK Unit mm ...
Страница 270: ...Chapter 8 Specifications 8 70 8 MEMO ...
Страница 271: ...1 Apx Appendix 1 Index 2 ...
Страница 275: ...Appendix 5 Apx MEMO ...
Страница 277: ......