Chapter 4 Explanation of Functions
4-34
4
■ Reset
This function resets the measurement value.
The measurement value can be reset by touching the “Reset” button. When
executing the “Peak measurement”, “Bottom measurement”, or “Peak to Peak
measurement”, the measurement value that has been on hold can be reset at
the desired timing.
The measurement value display of compact programmable display is turned to
the data unfixed status by executing “Reset” function, and the fixed
value(-999.999999), the setting fixed value for analog output (default:
“-10.800[V]”), and the judgment output are all turned to “OFF”.
For the details, refer to
“Timing Chart”
.
· The measurement value can be also reset by the reset terminal (RS1, RS2) of
the external input terminal.
“2-1 Functions and Arrangement of I/O Terminal Block”
When the reset input is set to “ON”, the “Judgment Output” is set to
“OFF”. This function is effective to perform judgment for each
measurement object at Peak, Bottom, and Peak to Peak measurements.
● How to use
1
Display the “OUT1 (or OUT2) operation” screen.
2
Touch the
Reset
key.
Touching the
Reset
key sets the temporary data
unfixed status, and the display value of compact
programmable display and analog output value are fixed.
* When the reset function is set to “ON”, the right screen appears temporarily,
and immediately after that, the left screen appears and the setting is released.
After the completion of reset, the measurement value is displayed after a
fixed duration passed.
Reset in progress
Reset is completed.
Selection screen of OUT1
Selection screen of OUT2
Содержание HL-C2 Series
Страница 32: ...Preface 30 MEMO ...
Страница 50: ...Chapter 1 Prior to Use 1 18 1 MEMO ...
Страница 65: ...Chapter 3 Programmable Display Operation 3 5 3 MEMO ...
Страница 164: ...Chapter 4 Explanation of Functions 4 90 4 MEMO ...
Страница 191: ...6 1 6 6 Maintenance and Inspection 6 1 Maintenance 6 2 6 2 Inspection 6 2 ...
Страница 200: ...Chapter 7 Troubleshooting 7 8 7 MEMO ...
Страница 249: ...Chapter 8 Specifications 8 49 8 8 5 Characteristics Beam Diameter 10mm type Unit mm 30mm type Unit mm ...
Страница 250: ...Chapter 8 Specifications 8 50 8 50mm type Unit mm 85mm type Unit mm ...
Страница 252: ...Chapter 8 Specifications 8 52 8 8mm type Unit mm 15mm type Unit mm ...
Страница 254: ...Chapter 8 Specifications 8 54 8 85mm type HL C208 HL C208 MK Unit mm 110mm type HL C211 HL C211 MK Unit mm ...
Страница 270: ...Chapter 8 Specifications 8 70 8 MEMO ...
Страница 271: ...1 Apx Appendix 1 Index 2 ...
Страница 275: ...Appendix 5 Apx MEMO ...
Страница 277: ......