Chapter 4 Explanation of Functions
4-23
4
4-3-2
OUT Setting
■ Output Selection
This function selects the output pattern of measurement values.
The below list shows the setting items and the output details.
Setting item
Function
A
Outputs the measurement value of the sensor head A.
B
Outputs the measurement value of the sensor head B.
-A
Outputs the measurement value of the sensor head A with putting a negative sign.
-B
Outputs the measurement value of the sensor head B with putting a negative sign.
A+B
Adds the measurement values of the sensor heads A&B and outputs the value.
-(A+B)
Adds the measurement values of the sensor heads A&B and outputs the value
with putting a negative sign.
A-B
Subtracts the measurement value of the sensor head B from that of sensor head A
and outputs the value.
B-A
Subtracts the measurement value of the sensor head A from that of sensor head B
and outputs the value.
A Tr
Outputs the measurement value of a transparent object by using the sensor head
A.
B Tr
Outputs the measurement value of a transparent object by using the sensor head
B.
-A Tr
Outputs the measurement value of transparent object A with putting a negative
sign.
-B Tr
Outputs the measurement value of transparent object B with putting a negative
sign.
A1+B1[Tr]
Adds the measurement values of 1st surface of a transparent object measured
by the sensor head A & B and outputs the value.
-(A1+B1) [Tr]
Adds the measurement values of 1st surface of a transparent object measured
by the sensor head A & B and outputs the value with putting a negative sign.
A1-B1[Tr]
Subtracts the measurement value (1st surface of a transparent object) of the sensor head B
from the measurement value (1st surface of a transparent object) of the sensor head A and
outputs the value.
B1-A1[Tr]
Subtracts the measurement value (1st surface of a transparent object) of the sensor head A
from the measurement value (1st surface of a transparent object) of the sensor head B and
outputs the value.
· Before measuring a transparent object, set “A Tr”, “B Tr”, “-A Tr”, “-B Tr”,
“A1+B1[Tr]”, “-(A1+B1)[Tr]”, “A1-B1[Tr]”, or “B1-A1[Tr]”. In this case, set
the “Installation Mode” to the specular reflection. (Note that the mounting
method of the sensor head is different between specular and diffuse reflection.
Also, set the “Measurement Surface Reference” and “Transparent Object”. If not
doing so, the measurement is executed up to the front surface of a transparent
object from the sensor head. Set the recommended measurement mode for
specular reflection.
· The settings of -A, -B, -(A+B), -A Tr, -B Tr, or -(A1+B1)[Tr] is reflected in all
outputs such as the measurement value display and analog output.
Содержание HL-C2 Series
Страница 32: ...Preface 30 MEMO ...
Страница 50: ...Chapter 1 Prior to Use 1 18 1 MEMO ...
Страница 65: ...Chapter 3 Programmable Display Operation 3 5 3 MEMO ...
Страница 164: ...Chapter 4 Explanation of Functions 4 90 4 MEMO ...
Страница 191: ...6 1 6 6 Maintenance and Inspection 6 1 Maintenance 6 2 6 2 Inspection 6 2 ...
Страница 200: ...Chapter 7 Troubleshooting 7 8 7 MEMO ...
Страница 249: ...Chapter 8 Specifications 8 49 8 8 5 Characteristics Beam Diameter 10mm type Unit mm 30mm type Unit mm ...
Страница 250: ...Chapter 8 Specifications 8 50 8 50mm type Unit mm 85mm type Unit mm ...
Страница 252: ...Chapter 8 Specifications 8 52 8 8mm type Unit mm 15mm type Unit mm ...
Страница 254: ...Chapter 8 Specifications 8 54 8 85mm type HL C208 HL C208 MK Unit mm 110mm type HL C211 HL C211 MK Unit mm ...
Страница 270: ...Chapter 8 Specifications 8 70 8 MEMO ...
Страница 271: ...1 Apx Appendix 1 Index 2 ...
Страница 275: ...Appendix 5 Apx MEMO ...
Страница 277: ......