26.6 Table of Special Internal Relays
26-69
WR904 (specified in word)
Relay
number
Name
Description
R9040
(R9131)
COM0 port operation mode flag
When using the general-purpose communication function, it is
ON.
When using a function outside of the general-purpose
communication function, it is OFF.
R9041
(R913E)
COM1 port PC (PLC) link flag
When using the PC (PLC) link function, it is ON.
R9042
(R9141)
COM2 port operation mode flag
When using the general-purpose communication function, it is
ON.
When using a function outside of the general-purpose
communication function, it is OFF.
R9043
Unused
R9044
(R913C)
COM1 port
SEND / RECV instruction
executable flag
Indicates the instruction with respect to the F145 (SEND) or
F146 (RECV) instruction of the COM1 port is executable /
non-executable.
OFF: non-executable (instruction executing)
ON: executable
R9045
(R913D)
COM1 port
SEND / RECV instruction
execution completion flag
Indicates the status with respect to the F145 (SEND) or F146
(RECV) instruction of the COM1 port.
OFF: normal completion
ON: abnormal completion (a communication error occurs)
The error code is stored to DT90124.
R9046
Unused
R9047
(R9140)
COM2 port communication error
flag
When performing data communication, if a transmission error
occurs, it is ON.
When requesting for sending via the F159 (MTRN)
instruction, it is OFF.
R9048
(R9142)
Reception completion flag for
COM2 port general-purpose
communication
For general communication, if the end character is received, it
is ON.
R9049
(R9143)
Sending completion flag for
COM2 port general-purpose
communication
For general-purpose communication, if end the transmission,
it is ON.
For general-purpose communication, if transmitting is
required, it is OFF.
R904A
(R9144)
COM2 port
SEND / RECV instruction
executable flag
Indicates the instruction with respect to the F145 (SEND) or
F146 (RECV) instruction of the COM2 port is executable /
non-executable.
OFF: non-executable (instruction executing)
ON: executable
R904B
(R9145)
COM2 port
SEND / RECV instruction
execution completion flag
Indicates the status with respect to the F145 (SEND) or F146
(RECV) instruction of the COM2 port.
OFF: normal completion
ON: abnormal completion (a communication error occurs)
The error code is stored to DT90125.
R904C-
R904F
Unused
(Note 1): R9040 - R904F will change even during a scanning cycle. In addition, the special internal relay in
parentheses is also allocated the same function.
WR905 (specified in word)
Relay
number
Name
Description
R9050
MEWNET-W0
PC (PLC) link transmission error
flag
When using MEWNET-W0
When a transmission error sent through the PC (PLC) link, it is ON.
When the setting of the PC (PLC) link area is abnormal, it is ON.
R9051-
R905F
Unused
Содержание FP-XH M8N16PD
Страница 1: ......
Страница 23: ...1 System Structure ...
Страница 39: ...2 Control Unit Specifications ...
Страница 48: ...Control Unit Specifications 2 10 ...
Страница 49: ...3 I O Allocation ...
Страница 77: ...4 Installation ...
Страница 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Страница 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Страница 105: ...6 Wiring of Motion I O Parts ...
Страница 116: ...Wiring of Motion I O Parts 6 12 ...
Страница 117: ...7 Power On Off and Check Items ...
Страница 124: ...Power On Off and Check Items 7 8 ...
Страница 125: ...8 Steps Before Running ...
Страница 134: ...Steps Before Running 8 10 KEYPOINTS Port No can be confirmed through the computer s device manager ...
Страница 142: ...Steps Before Running 8 18 ...
Страница 143: ...9 Setting of Position Control Parameters ...
Страница 159: ...10 Transfer to Unit and Commissioning ...
Страница 181: ...11 Automatic Operation Position Control ...
Страница 193: ...11 2 Interpolation Control 11 13 ...
Страница 209: ...12 Automatic Operation Synchronous Control ...
Страница 251: ...13 Manual Operation JOG Operation ...
Страница 256: ...Manual Operation JOG Operation 13 6 ...
Страница 257: ...14 Manual Operation Home Return ...
Страница 264: ...Manual Operation Home Return 14 8 ...
Страница 265: ...15 Pulse Input Function ...
Страница 278: ...Pulse Input Function 15 14 ...
Страница 279: ...16 Stop Function ...
Страница 285: ...17 Auxiliary Function ...
Страница 326: ...Auxiliary Function 17 42 Note Refer to the latest instruction manual and technical materials of the servo amplifier ...
Страница 329: ...18 Instruction Reference ...
Страница 357: ...19 Error Warning Annunciation Function ...
Страница 386: ...Error Warning Annunciation Function 19 30 ...
Страница 387: ...20 Troubleshooting ...
Страница 402: ...Troubleshooting 20 16 ...
Страница 403: ...21 Memory Master Memory Cassette ...
Страница 418: ...Memory Master Memory Cassette 21 16 ...
Страница 419: ...22 Security Functions ...
Страница 430: ...Security Functions 22 12 ...
Страница 431: ...23 General purpose Input High speed counter Function ...
Страница 448: ...General purpose Input High speed counter Function 23 18 ...
Страница 449: ...24 Other Functions ...
Страница 452: ...Other Functions 24 4 ...
Страница 453: ...25 Maintenance and Inspection ...
Страница 457: ...26 Specifications ...
Страница 552: ...Specifications 26 96 ...
Страница 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Страница 554: ......
Страница 555: ......
Страница 556: ......