![Panasonic FP-XH M8N16PD Скачать руководство пользователя страница 500](http://html.mh-extra.com/html/panasonic/fp-xh-m8n16pd/fp-xh-m8n16pd_user-manual_262677500.webp)
Specifications
26-44
Positioning data setting area
For details of the starting addresses of each positioning table, refer to the list on page 26-46
and after.
Offset
Address
Name
Default Setting range and description
H0
Control code
H0
Sets the position setting mode and acceleration/deceleration pattern
for the positioning operation.
bit
Name
Default
Description
0
Increment/absolute
setting
H0
0: Increment mode
1: Absolute mode
1
Acceleration/deceler
ation pattern setting
H0
0: Linear
acceleration/deceleration
1: S-shaped
acceleration/deceleration
15-2
-
-
-
H1
Operation pattern H0
Sets the single and interpolation patterns for the positioning
operation.The relation of the interpolation depends on the settings in
the axis group setting area in the common area of the positioning unit
memory. In the interpolation operation, the setting for the axis with the
smallest number in an axis group is effective.
bit
Name
Default
Description
7-0
Control
pattern
H0
H0: E-point control (End point control)
H1: P-point control (Pass point control)
H2: C-point control (Continuance point
control)
H3: J-point control (Speed point control)
Any other settings will be errors.
15-8
Inter-
polation
setting
H0
H0: Linear interpolation (Composite
speed)
H1: Linear interpolation (Long axis speed)
H10: Circular interpolation (Center
point/CW direction)
H11: Circular interpolation (Center
point/CCW direction)
H20: Circular interpolation (Pass point):
H50: Spiral interpolation (Center point/CW
direction/X-axis movemet)
H51: Spiral interpolation (Center
point/CCW direction/X-axis movemet)
H52: Spiral interpolation (Center point/CW
direction/Y-axis movemet)
H53: Spiral interpolation (Center
point/CCW direction/Y-axis movemet)
H54: Spiral interpolation (Center point/CW
direction/Z-axis movemet)
H55: Spiral interpolation (Center
point/CCW direction/Z-axis movemet)
H60: Spiral interpolation (Pass point/X-
axis movement)
H61: Spiral interpolation (Pass point/Y-
axis movement)
H62: Spiral interpolation (Pass point/Z-
axis movement)
Any other settings will be errors.
H2-H3
Reserved for
system
-
-
H4
Positioning
acceleration time
K100
Sets the acceleration and deceleration time for the positioning
operation. The acceleration time and deceleration time can be set
individually. In the interpolation operation, the setting for the axis with
the smallest number in an axis group is effective.
Setting range: 0-10,000 (ms)
Any other settings will be errors.
H5
Positioning
deceleration time
Содержание FP-XH M8N16PD
Страница 1: ......
Страница 23: ...1 System Structure ...
Страница 39: ...2 Control Unit Specifications ...
Страница 48: ...Control Unit Specifications 2 10 ...
Страница 49: ...3 I O Allocation ...
Страница 77: ...4 Installation ...
Страница 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Страница 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Страница 105: ...6 Wiring of Motion I O Parts ...
Страница 116: ...Wiring of Motion I O Parts 6 12 ...
Страница 117: ...7 Power On Off and Check Items ...
Страница 124: ...Power On Off and Check Items 7 8 ...
Страница 125: ...8 Steps Before Running ...
Страница 134: ...Steps Before Running 8 10 KEYPOINTS Port No can be confirmed through the computer s device manager ...
Страница 142: ...Steps Before Running 8 18 ...
Страница 143: ...9 Setting of Position Control Parameters ...
Страница 159: ...10 Transfer to Unit and Commissioning ...
Страница 181: ...11 Automatic Operation Position Control ...
Страница 193: ...11 2 Interpolation Control 11 13 ...
Страница 209: ...12 Automatic Operation Synchronous Control ...
Страница 251: ...13 Manual Operation JOG Operation ...
Страница 256: ...Manual Operation JOG Operation 13 6 ...
Страница 257: ...14 Manual Operation Home Return ...
Страница 264: ...Manual Operation Home Return 14 8 ...
Страница 265: ...15 Pulse Input Function ...
Страница 278: ...Pulse Input Function 15 14 ...
Страница 279: ...16 Stop Function ...
Страница 285: ...17 Auxiliary Function ...
Страница 326: ...Auxiliary Function 17 42 Note Refer to the latest instruction manual and technical materials of the servo amplifier ...
Страница 329: ...18 Instruction Reference ...
Страница 357: ...19 Error Warning Annunciation Function ...
Страница 386: ...Error Warning Annunciation Function 19 30 ...
Страница 387: ...20 Troubleshooting ...
Страница 402: ...Troubleshooting 20 16 ...
Страница 403: ...21 Memory Master Memory Cassette ...
Страница 418: ...Memory Master Memory Cassette 21 16 ...
Страница 419: ...22 Security Functions ...
Страница 430: ...Security Functions 22 12 ...
Страница 431: ...23 General purpose Input High speed counter Function ...
Страница 448: ...General purpose Input High speed counter Function 23 18 ...
Страница 449: ...24 Other Functions ...
Страница 452: ...Other Functions 24 4 ...
Страница 453: ...25 Maintenance and Inspection ...
Страница 457: ...26 Specifications ...
Страница 552: ...Specifications 26 96 ...
Страница 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Страница 554: ......
Страница 555: ......
Страница 556: ......