![Panasonic FP-XH M8N16PD Скачать руководство пользователя страница 215](http://html.mh-extra.com/html/panasonic/fp-xh-m8n16pd/fp-xh-m8n16pd_user-manual_262677215.webp)
12.3 Start and Cancel of Synchronous Control
12-7
Operations while synchronous control is performed/canceled
Operation request axis
Operation while synchronous control
is performed
Operation while
synchronous control
is canceled
Master axis set
Slave axis set
Master/Slave axis set
Home return
No
The master axis performs
a home return.
The slave axes do not
perform a home return
but operate in
synchronization with
output from the master
axis.
For performing home
return, cancel the
synchronous control and
operate.
No
The slave axes do
not operate in
response to
operation requests.
Yes
The master axis or slave
axes will perform a home
return only if the master
axis or the slave axes are
so requested.
JOG operation
Yes
The slave axes operate
in synchronization with
the operation request of
the master axis.
Yes
The master axis or slave
axes will go into JOG
operation only if the
master axis or the slave
axes are so requested.
Positioning
Single axis
Interpolation
Yes
Interpolation will be
executed upon request if
the master axis is the
start axis of interpolation.
The slave axes operate
in synchronization with
the master axis.
Yes
Interpolation will be
executed upon request if
the requested axis is the
start axis of interpolation.
Stop
functions
System stop
All the axes come to a stop regardless of the synchronization settings.
Emergency
stop
Yes
The master axis comes
to a stop upon request.
The slave axes come to
a stop in synchronization
with the master axis.
Yes
Only axes
requested come to a
stop.
The master axis and
other salve axes set
on the same master
axis continue
operating.
Yes
Only axes requested
come to a stop.
(All the axes in
interpolation operation
come to a stop.)
Deceleration
stop
Limit stop
The master axis and all the slave axes come to a
stop.
Only axes resulting in a
limit error come to a stop.
Error stop
Only axes resulting in an
error come to a stop.
(Note 1): When an error occurs in the master axis and slave axes, all axes will stop at the stop time of tha master axis.
(Note 2): When a limit stop or error stop occurs in slave axes, the master axis will stop. Consequently all slave axes
will stop at the stop time of the master axis.
Содержание FP-XH M8N16PD
Страница 1: ......
Страница 23: ...1 System Structure ...
Страница 39: ...2 Control Unit Specifications ...
Страница 48: ...Control Unit Specifications 2 10 ...
Страница 49: ...3 I O Allocation ...
Страница 77: ...4 Installation ...
Страница 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Страница 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Страница 105: ...6 Wiring of Motion I O Parts ...
Страница 116: ...Wiring of Motion I O Parts 6 12 ...
Страница 117: ...7 Power On Off and Check Items ...
Страница 124: ...Power On Off and Check Items 7 8 ...
Страница 125: ...8 Steps Before Running ...
Страница 134: ...Steps Before Running 8 10 KEYPOINTS Port No can be confirmed through the computer s device manager ...
Страница 142: ...Steps Before Running 8 18 ...
Страница 143: ...9 Setting of Position Control Parameters ...
Страница 159: ...10 Transfer to Unit and Commissioning ...
Страница 181: ...11 Automatic Operation Position Control ...
Страница 193: ...11 2 Interpolation Control 11 13 ...
Страница 209: ...12 Automatic Operation Synchronous Control ...
Страница 251: ...13 Manual Operation JOG Operation ...
Страница 256: ...Manual Operation JOG Operation 13 6 ...
Страница 257: ...14 Manual Operation Home Return ...
Страница 264: ...Manual Operation Home Return 14 8 ...
Страница 265: ...15 Pulse Input Function ...
Страница 278: ...Pulse Input Function 15 14 ...
Страница 279: ...16 Stop Function ...
Страница 285: ...17 Auxiliary Function ...
Страница 326: ...Auxiliary Function 17 42 Note Refer to the latest instruction manual and technical materials of the servo amplifier ...
Страница 329: ...18 Instruction Reference ...
Страница 357: ...19 Error Warning Annunciation Function ...
Страница 386: ...Error Warning Annunciation Function 19 30 ...
Страница 387: ...20 Troubleshooting ...
Страница 402: ...Troubleshooting 20 16 ...
Страница 403: ...21 Memory Master Memory Cassette ...
Страница 418: ...Memory Master Memory Cassette 21 16 ...
Страница 419: ...22 Security Functions ...
Страница 430: ...Security Functions 22 12 ...
Страница 431: ...23 General purpose Input High speed counter Function ...
Страница 448: ...General purpose Input High speed counter Function 23 18 ...
Страница 449: ...24 Other Functions ...
Страница 452: ...Other Functions 24 4 ...
Страница 453: ...25 Maintenance and Inspection ...
Страница 457: ...26 Specifications ...
Страница 552: ...Specifications 26 96 ...
Страница 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Страница 554: ......
Страница 555: ......
Страница 556: ......