26.1 Control Unit Specifications
26-7
Item
Specifications
M
anual
oper
at
ion
JOG
operation
Speed
reference
range
Pulse: 1-2,147,482,624 pps
µm; 1-2,147,482,624 µm/s
inch: 0.001-2,147,482.624 inch/s
degree: 0.001-2,147,482.624 rev/s
Acceleration/
deceleration
method
Linear acceleration/deceleration, S acceleration/deceleration
Acceleration
time
0-0,000ms (Settable by 1 ms)
Deceleration
time
0-10,000ms (Settable by 1 ms)
Home return
Speed
reference
range
pulse
:
1-2,147,482,624 pps
µm
:
1-2,147,482,624 µm/s
inch
:
0.0010-2,147,482.624 inch/s
degree
:
0.001-2,147,482.624 rev/s
Acceleration/
deceleration
method
Linear acceleration/deceleration
Acceleration
time
0-10,000 ms (Settable by 1 ms)
Deceleration
time
0-10,000 ms (Settable by 1 ms)
Return
method
DOG method (3 types), Limit method (2 types), Data set method, Z phase
method, Stop-on-contact method (2 types)
Pulsar
operation
(Note 1)
Number of
channels
Max. 4 channels (Used in combination with the high-speed counter function.)
Speed
reference
range
Operates synchronously with pulsar input. (Note 1)
S
top
func
tion
Stop operation type
System stop, emergency stop, limit stop, error stop, deceleration stop, pause
Stop deceleration time
The system stops when the deceleration time of all axes reaches 1 ms.
The deceleration time of emergency stop, limit stop, error stop, deceleration
stop and pause is 0 to 10,000 ms. (Settable by 1 ms.)
High-speed
counter function
(Note 1)
Number of
channels
Max. 4 channels (Used in combination with the pulsar input.)
Counting
range
Counting range: -2,147,483,648 - 2,147,483,647 pulses
Input mode
Phase difference input, Direction discrimination input, Individual input
(transfer multiple available for each.)
Memory backup
Parameters and positioning data are saved in the flash memory. (Batteryless)
Other functions
Software limit, current value update, target speed change, target position
change, tool operation, torque monitor, actual speed monitor, torque limit,
AMP parameter R/W, AMP status monitor, RTEX general-purpose monitor
input (max. 2 points), RTEX operation output (max. 2 points)
(Note 1): The pulsar input function and high-speed counter function use the same pulse input terminal. Therefore, the
both functions cannot be used simultaneously.
Содержание FP-XH M8N16PD
Страница 1: ......
Страница 23: ...1 System Structure ...
Страница 39: ...2 Control Unit Specifications ...
Страница 48: ...Control Unit Specifications 2 10 ...
Страница 49: ...3 I O Allocation ...
Страница 77: ...4 Installation ...
Страница 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Страница 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Страница 105: ...6 Wiring of Motion I O Parts ...
Страница 116: ...Wiring of Motion I O Parts 6 12 ...
Страница 117: ...7 Power On Off and Check Items ...
Страница 124: ...Power On Off and Check Items 7 8 ...
Страница 125: ...8 Steps Before Running ...
Страница 134: ...Steps Before Running 8 10 KEYPOINTS Port No can be confirmed through the computer s device manager ...
Страница 142: ...Steps Before Running 8 18 ...
Страница 143: ...9 Setting of Position Control Parameters ...
Страница 159: ...10 Transfer to Unit and Commissioning ...
Страница 181: ...11 Automatic Operation Position Control ...
Страница 193: ...11 2 Interpolation Control 11 13 ...
Страница 209: ...12 Automatic Operation Synchronous Control ...
Страница 251: ...13 Manual Operation JOG Operation ...
Страница 256: ...Manual Operation JOG Operation 13 6 ...
Страница 257: ...14 Manual Operation Home Return ...
Страница 264: ...Manual Operation Home Return 14 8 ...
Страница 265: ...15 Pulse Input Function ...
Страница 278: ...Pulse Input Function 15 14 ...
Страница 279: ...16 Stop Function ...
Страница 285: ...17 Auxiliary Function ...
Страница 326: ...Auxiliary Function 17 42 Note Refer to the latest instruction manual and technical materials of the servo amplifier ...
Страница 329: ...18 Instruction Reference ...
Страница 357: ...19 Error Warning Annunciation Function ...
Страница 386: ...Error Warning Annunciation Function 19 30 ...
Страница 387: ...20 Troubleshooting ...
Страница 402: ...Troubleshooting 20 16 ...
Страница 403: ...21 Memory Master Memory Cassette ...
Страница 418: ...Memory Master Memory Cassette 21 16 ...
Страница 419: ...22 Security Functions ...
Страница 430: ...Security Functions 22 12 ...
Страница 431: ...23 General purpose Input High speed counter Function ...
Страница 448: ...General purpose Input High speed counter Function 23 18 ...
Страница 449: ...24 Other Functions ...
Страница 452: ...Other Functions 24 4 ...
Страница 453: ...25 Maintenance and Inspection ...
Страница 457: ...26 Specifications ...
Страница 552: ...Specifications 26 96 ...
Страница 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Страница 554: ......
Страница 555: ......
Страница 556: ......