Mounting terminal plug B
13
Setscrew
Body
Grounding
terminal block
Cover
Cable clamp
Terminal block
Lever(Green)
Voltage
indication
label
Terminal screw
(M4)
Securing screw
Ground
Terminal plug B
100V 200V
Notes
●
Use cables of 1.25 mm
2
to 2.0mm
2
in size.
●
Connect a single core to the grounding terminal block.
●
To prevent improper use of operating voltage (100V
or 200V) indicated in the operating voltage category,
be sure to affix a voltage indication label, which
comes with this product, to the bottom of the plug.
1
.Remove the setscrews, and then dismount the cover.
2
.Unfasten the cable clamp securing screw, and
then put the electrical cable into the cover.
3
.Connect the electrical cables to the terminal block
by the use of a crimp-style terminal or winding the
cable around the terminal, respectively.
4
.Put the cover in the duct, and then fix it with the setscrews.
5
.Fasten the setscrews of the cable clamp to fix the cables.
Connecting electrical cables
1 Adjust the polarity
2 Insert
3 Rotate90°
clockwise
●Put the outlet plug lever in the duct in line with
its polarity indication (green line), and then
rotate the plug clockwise by 90 degrees.
Mounting plug
●プラグのレバーを引き下げて、左に90°回転させる。
●Pull up the plug lever, and then rotate it
counterclockwise by 90 degrees.
Dismounting plug
●
Do not mount the clamp in the opposite direction.
●
Do not use plugs (with an orange lever) for Factory Line 30.
Doing so may result in an electric shock or a fire.
Caution
●
Do not mount the clamp in the opposite direction.
●
Securely fasten the terminal screws.
Doing so may result in an electric shock or a fire.
Caution
Polarity indication
(Grounding side)
(Green line)
Lever(Green)
Polarity indication
(Grounding side)
(Green line)
Mounting outlet plug
12
Ground
Outlet plug
●Put the outlet plug lever in the duct in line with
its polarity indication (green line), and then
rotate the plug clockwise by 90 degrees.
Mounting plug
●プラグのレバーを引き下げて、左に90°回転させる。
●Pull up the plug lever, and then rotate it
counterclockwise by 90 degrees.
Dismounting plug
1 Adjust the polarity
2 Insert
3 Rotate90°
clockwise
●
Do not mount the clamp in the opposite direction.
Doing so may result in an electric shock or a fire.
●
Do not use plugs (with an orange lever) for Factory Line 30.
Doing so may result in an electric shock or a fire.
Caution
Polarity indication
(Grounding side)
(Green line)
Lever
(Green)
Polarity indication
(Grounding side)
(Green line)
Polarity indication
(Grounding side)
(Green line)
Voltage
indication label
18
19