Warning
● Do not modify to products in any way.
May cause fire, electric shock or damage due to falling
of equipment.
● Do not install parts of incompatible.
May cause fire, electric shock or damage due to falling
of equipment.
● Do not mount any bracket other than dedicated
bracket to the Factory Line 100 or 60, or do not
apply weight exceeding that of the dedicated
bracket (allowable suspension load of hanger: 20
kg) to the Factory Line.
Doing so will result in a drop.
● Do not install the illuminator that becomes a high
temperature like the white heat ball etc.
Not doing so will result in an electric shock, a fire.
● If any abnormality occurs, immediately turn OFF the
power supply, and then contact your electrical worker
to take necessary actions.(In such case, be sure to
pass Instruction and Installation Manuals )
Not doing so will result in an electric shock, a fire, or a drop.
● Use the rated voltage within the load capacity that is always displayed.
Not doing so will result in a fire.
● Use Fluorescent lighting plug below a permissible load.
Not doing so will result in a fire, or a drop.
Caution
● this product is dedicated to ordinary indoor use, Do not
use it at the place which is subject to the influence of heat,
such as the upper part of a heater, or a place with moist
place and vibration, which receives blowing in of rain, and
a moist,,where corrosive gas, where the smoke rises
・A place with moist place and vibration
・A place which receives blowing in of rain, and a moist place
・A place where corrosive gas, where the smoke rises
・The place which is subject to the influence of
heat, such as the upper part of a heater.
Not doing so will result in an electric shock, a fire, or a drop.
● Do not slide putting the plug in the duct.
Poor contact will cause a fire.
● Do not pull the plug cable.
Doing so may result in faulty connection, thus leading to a fire.
● Delicated plug for 100V in the Factory Line 100 or
60,do not use the Factory Line30.Because of the
different ground-taking.Similarly,the plug for the Factory
Line 30,not used 2P 20 A line circuit in the Factory Line
100・60.
Not doing so may result in an electric shock or a fire.
● Before check for the product, be sure to turn OFF the power supply.
Not doing so may result in an electric shock.
● If an earthquake occurs, turn OFF the power supply, and then
ensure that thorough mounting strength is provided.If NOT,
consult with your electrical contractor. In such case, be sure to
pass these Installation and Instruction Manuals to the contractor.
Not doing so will result in a drop.
● Use the range of -10 ℃ ~ 40 ℃ ambient temperature
The use without of range, burn, or cause a fire.
● Attach the plug in the right direction.
If it attaches to reverse, it will become a cause of an electric
shock, a fire, and fall.
● Do not apply directly weight to an outlet of the outlet
plug and the reeler outlet plug.
Not doing so will result in an electric shock, a fire, or a drop.
● Use this product for the transmission of information,
The transmission performance might be deteriorated
because of the signal decay in connected part.
● There is longevity in Factory Line 100・60, and a
standard use period is ten years.
Even if abnormality is not found in externals, the check
exchange is done internally because it is deteriorated
Instruction Manual
Factory Line 100・60
For keeping
■Be sure to read this Instruction Manual before use, and then properly use the product.
■Ask an electrical contractor for troubleshooting and maintenance such as expansion of this product. In
such case, be sure to pass these Instruction and Installation Manuals to the contractor.
■Mounting additional outlet plug requires no qualification as an electrical worker.
Note:Before mounting/dismounting or relocating plugs, be sure to turn OFF power supply
■Be sure to keep this Instruction Manual for future reference, and be sure to hand this manual to user.
There is longevity in Factory Line 100・60, and a standard use period is ten years. It becomes impossible to use finally
due to the deterioration of internal if it uses it exceeding the service life. Deterioration advances every year though
it differs in the environmental condition and the service space. In order to use the factry-line for a long time,Please
contact the specialist in the construction shop etc. when it checks, and trouble is found, and receive the check by the
specialist in the construction shop etc. once every three years. Please be sure to observe the following, and the check.
The precautions describe what must be observed not to harm humans nor cause property damage.
Safety precautions
Be sure to observe the precautions fully
2013
©
Panasonic Corporation Power Components Business Unit
1048,kadoma,kadoma,osaka,571-8686,japan Tel81-06-6908-1131