to
assign
the
same
on
[1]:
[2]:
on
[3]:
on
until
desired disconnect
time appears
. . . . . .
.
.
. .
. .
.
. .
. . .
default
[1 9] [N EXT] [A] [SELECT] [M EMORY] [END]
or
[1 9] [NEXT] [NEXT] [SELECT] [M EMORY] [END]
:
_ _ _ _ _ _ _
until the desired CO number appears
Description
A certain amount of time is needed for a outside
call to be released, this is necessary so that new
calls may be attempted after disconnecting with
the previous calls.
There are two choices available,
I. 5
and 4. 0
seconds.
The time you select m ust be longer than rhe
requirements from your Central Office or host
PBX.
Programming
1.
Dial (1 9) .
"DISCONNECT TIME" will be displayed.
2 .
Press the NEXT button.
"ENTER CO NO" will be displayed.
3.
Press the NEXT button.
"CO
I: I.5
SEC" will be displayed and
"I. 5
SEC" will blink.
4.
Press the SELECT button to alternate be
tween
1 . 5
sec and 4. 0 sec.
5.
Press the MEMOR Y button.
The blinking L CD will stop.
2-27
6.
Repeat steps 3 to
5,
to set the disconnect time
for the other CO 's.
7.
To rerum to the initial program mode, press
the END button.
Conditions
When you start the programming from step
I,
you may dial the desired CO n umber instead of
the NEXT button at step 3.
• The PREV button allows you to go to the
previous CO for displaying the disconnect
time.
Example:
•4. 0 sec on all 3 CO=
[1 9] [N EXT] [*] [SELECT] [MEMORY] [END]
To
make program change
CO(s)
I
1.5
sec
4.0 sec
X
Programming Table
See page
5-I6.
2
X
3
X