99
DP-8032/8025
2008
Ver. 1.2
Note:
1. While updating the firmware code, the display may become garbled, however, it will return to
normal upon completion of the firmware update.
2. Please refer to the Firmware Update Tool OI for additional details.
3. The suffix "_xx" for the Folder Name or File Name may not exist depending on the destination
location.
5) After the Firmware Update is completed, enter the F5 & F6 Parameters according to the lists printed in
step 3).
3.7.4.
Updating the Firmware using the Master Firmware Card (Alternate method)
1. Before starting, print the F5/F6 Parameters List (Copy Service Mode F9-03-00).
2. Turn the Power Switch on the left side and the Main Power Switch on the back of the machine to the
OFF position. (Refer to 3.7.7.)
3. Install the appropriate Master Firmware Card into the machine.
4. Turn the Main Power Switch on the back and the Power Switch on the left side of the machine to the
ON position.
5. Press the
“FUNCTION”
,
“ORIGINAL SIZE (LEDGER/A3)”
, and the
“3”
keys simultaneously.
6. Input the password, and select the
“OK”
button to enter the Service Mode (default password is
00000000
).
Note:
If the Data Security Kit is installed, Enter the password, and select “OK” button (default password is
00000000
).
7. Perform the Copy Service Mode F9-07-00 (Update From Master Card).
8. The firmware is copied into the machine.
9. After the update is completed, the machine reboots itself and returns to standby.
10. Turn the Power Switch on the left side and the Main Power Switch on the back of the machine to the
OFF position. (Refer to 3.7.7.)
11. Remove the Master Firmware Card from the machine.
12. Turn the Main Power Switch on the back and the Power Switch on the left side of the machine to the
ON position.
13. Reprogram the F5 & F6 Parameters according to the lists printed in Step 1. above if the settings are
other than factory default.
Note:
After the update is completed, the machine reboots itself and returns to standby mode.
Repeat the above steps if there are additional firmware code files to be updated.
Confirm that the update was successfully completed by checking the Firmware Version with F9
Parameters F9-02-xx.
Caution:
If the unit does not boot up properly in step 8, refer to 3.7.8. (Firmware Emergency Recovery)
3.7.5.
Creating a Master Firmware Card
A. Utilizing the Firmware Update Kit
1) Install the Local Firmware Update Tool to your PC
The Tool can be downloaded from your sales company’s Web site, or the PCC Service Web site.
Please refer to the Operating Instructions of the Tool for details.
Operating Instructions:
\xFirmware\Tools\Firmup\FIRMUP OI.pdf (Refer to the
Local Firmware Update Tool OI
on the CD)
Setup:
\xFirmware\Tools\Firmup\Setup\Setup.exe
Содержание DP-8032
Страница 2: ...2 ...
Страница 3: ...3 ...
Страница 5: ...5 Hinweis Beispiel ...
Страница 9: ...9 ...
Страница 10: ...10 ...
Страница 11: ...11 ...
Страница 12: ...12 memo ...
Страница 368: ...DZSD001829 15 Panasonic Software Operating Instructions Network Firmware Update Tool for Service Technicians Version 3 ...
Страница 381: ...Network Firmware Update Tool LAN Page 14 13 Confirm the message in the text box and click OK to close the tool or ...
Страница 382: ...DZSD000965 18 Panasonic Software Operating Instructions Local Firmware Update Tool for Service Technicians Version 3 ...
Страница 397: ...Published in Japan ...