Information Codes Table (For Facsimile)
Fax Information Codes
Code
Mode
Phase
Description of Problem
Possible Cause(s)
012
RCV
C, D
The length of the received
document is over 2 m.
030
XMT
B
Read Point Sensor does not
activate within 4 seconds after the
document starts feeding.
Document not set properly.
Defective Read Point Sensor.
031
XMT
COPY
C
Transmitting document was longer
than 2,000 mm (or 78.7 in).
(Super Fine: 1,000 mm (or 39.4 in),
600 dpi: 430 mm (or 16.2 in))
Document may be jammed.
Defective Read Point Sensor.
061
-
A
ADF Door is open.
Cover not firmly closed.
Connectors not firmly connected.
200
RCV
C
Decoding process is not completed
at the end of phase C.
Defective FXB PCB.
212
XMT
RCV
A-E
Interface error occurred between
the CPU and modem.
Modem defective. (FXB PCB)
Software problem occurred. (SC PCB)
301
XMT
RCV
System fault.
Software problem occurred. (SC PCB)
331
XMT
C
8-minutes timer error.
(Germany only)
400
XMT
B
T1 timer (35±5 sec) elapsed
without detecting 300 bps signal.
Wrong number dialed and the START
button is pushed.
Telephone line disconnected while
dialing.
FXB PCB (Modem) or MJR PCB
defective.
Receiver defective. (It may only be
transmitting CED)
401
XMT
B
DCN was returned from receiver
while transmitter is waiting for CFR
or FTT.
Your machine's ID Number not
programmed.
Possible incompatibility or incorrect
Password (Password Reception,
Selective Receive).
Mailbox full.
402
XMT
B
DCN was returned from receiver
while transmitter is waiting for
NSF/DIS.
Receiver working in non-CCITT mode
only. (Possible incompatibility)
403
RCV
(Polling)
B
Transmitter had no polling
function.
"POLLED=ON" (polling XMT ready)
not set at the transmitter.
Document to be transmitted not placed
at the transmitter.
404
XMT
B
Transmitter sent NSS (or DCS)
followed by TCF three times, but
the receiver did not respond. (CFR
or FTT is usually returned)
Receiver defective. (Modem, MJR
PCB, etc.)
FXB PCB or MJR PCB defective.
Receiver disconnects line during first
NSS (or DCS) transmitted.
405
XMT
B
Transmitter received FTT after it
transmitted TCF at 2400 bps.
Received RTN after
communicating at 2400 bps.
Line quality poor. (TCF is damaged
due to line noise)
Receiver defective. (Modem, MJR
PCB, etc.)
FXB PCB or MJR PCB defective.
Содержание DP-8032
Страница 2: ...2 ...
Страница 3: ...3 ...
Страница 5: ...5 Hinweis Beispiel ...
Страница 9: ...9 ...
Страница 10: ...10 ...
Страница 11: ...11 ...
Страница 12: ...12 memo ...
Страница 368: ...DZSD001829 15 Panasonic Software Operating Instructions Network Firmware Update Tool for Service Technicians Version 3 ...
Страница 381: ...Network Firmware Update Tool LAN Page 14 13 Confirm the message in the text box and click OK to close the tool or ...
Страница 382: ...DZSD000965 18 Panasonic Software Operating Instructions Local Firmware Update Tool for Service Technicians Version 3 ...
Страница 397: ...Published in Japan ...