3 Maintenance, Adjustments and Check Points
3.1.
Preventive Maintenance
Preventive maintenance is performed at specific intervals, and consists of machine
cleaning, and parts replacement.
It is essential to perform these service activities properly, and at the specified intervals
for customer satisfaction.
The purpose of this service is to maintain machine performance, and image quality.
- You should prepare the replacement parts, and cleaning tools beforehand.
- After completing the preventive maintenance, discard the used parts, and
packaging in accordance with local regulations, and clean the surrounding
area.
- Before servicing the equipment, turn the power switches Off, and disconnect
the power cord from the wall outlet.
- Before using solvents such as IPA (Isopropyl alcohol), put on rubber gloves,
and wear eye protection.
1
Timing
- Perform the preventive maintenance in accordance with the Preventive
Maintenance Check List (refer to 3.4) in the service manual.
2
Cleaning the Rollers
- Rollers should be cleaned with water, and a soft cloth.
- Use the IPA (Isopropyl Alcohol) sparingly.
3
Disassembly and Adjustment Precautions
Turn the Power Switch on the Right Side of the machine to the OFF
position, and then unplug the AC Power Cord from the wall outlet
before disassembling the machine. (During a Lightning Storm, to
prevent electrocution disconnect the Telephone Line Cable first
before unplugging the AC Power Cord.)
CAUTION!
- After taking the unit apart, do not attempt to operate the machine.
- When operating the machine with covers removed, be careful, and avoid clothing
from being caught by moving components.
-
- When handling the drum, follow the precautions listed in section 3.3.
- Ensure to use correct screws.
- Use toothed lock washers for the installation of ground wires to ensure electrical
continuity.
- To reassemble, reverse the sequence of disassembly, unless otherwise specified.
- Blown fuses should only be replaced with fuses of the same specified rating.
While the electricity is applied to the unit, do not connect nor disconnect the
connectors on any PC Board.
Содержание DP-8020E
Страница 2: ...2 ...
Страница 5: ...5 ...
Страница 10: ...10 ...
Страница 11: ...11 ...
Страница 12: ...12 ...
Страница 62: ...62 SEP 2006 Ver 1 0 DP 8020E 8020P 8016P 24 Remove the LCD Holder 520 25 Remove the LCD Module 519 ...
Страница 105: ...105 SEP 2006 Ver 1 0 DP 8020E 8020P 8016P DETAIL A 28 35 31 32 33 34 30 29 ...
Страница 185: ...185 SEP 2006 Ver 1 0 DP 8020E 8020P 8016P 3 10 10 MJR PC Board CN22 Refer to FXB PC Board CN25 Refer to FXB PC Board ...
Страница 466: ...466 SEP 2006 Ver 1 0 DP 8020E 8020P 8016P memo ...
Страница 467: ...DZSD001829 14 Panasonic Software Operating Instructions Network Firmware Update Tool for Service Technicians Version 3 ...
Страница 482: ...DZSD000965 17 Panasonic Software Operating Instructions Local Firmware Update Tool for Service Technicians Version 3 ...
Страница 493: ...Local Firmware Update Tool Parallel USB Port Page 12 5b4 Firmware Code File selection is completed Click Next ...
Страница 497: ......
Страница 498: ...Published in Japan ...