![Panasonic DLP PT-FRZ50 Скачать руководство пользователя страница 121](http://html.mh-extra.com/html/panasonic/dlp-pt-frz50/dlp-pt-frz50_operating-instructions-functional-manual_275433121.webp)
Chapter 4
Settings — [NETWORK] menu
ENGLISH - 121
[AUTO]
For DIGITAL LINK
l
―
l
l
For long reach
―
l
l
l
For Ethernet
―
―
l
*1
―
[DIGITAL LINK]
l
―
l
l
[LONG REACH]
―
l
l
l
[ETHERNET]
―
―
l
*1
―
*1 Communication via a twisted-pair-cable transmitter is not available. Connect the projector to the network directly.
Note
f
For the signal with the resolution of 1 920 x 1 200 dots or less, the maximum transmission distance is 100 m (328'1") when connected with
the DIGITAL LINK communication method. For the signal with the resolution exceeding 1 920 x 1 200 dots, the maximum transmission
distance is 50 m (164'1").
f
The maximum transmission distance when connected with the long-reach communication method is 150 m (492'2"). In this case, the signal
that the projector can receive is only up to 1080/60p (1 920 x 1 080 dots, dot clock frequency 148.5 MHz).
f
If the communication method of the twist-pair-cable transmitter is set to long reach, the projector will connect with long-reach communication
method when the item is set to [AUTO]. To connect with the optional DIGITAL LINK Switcher (Model No.: ET-YFB200G) with the long-reach
communication method, set the item to [LONG REACH].
f
Even when the item is set to [LONG REACH], connection will not be made correctly if the twist-pair-cable transmitter is not supporting the
long-reach communication method.
[DIGITAL LINK STATUS]
Display the DIGITAL LINK connection environment.
1) Press
as
to select [DIGITAL LINK].
2) Press the <ENTER> button.
f
The
[DIGITAL LINK]
screen is displayed.
3) Press
as
to select [DIGITAL LINK STATUS].
4) Press the <ENTER> button.
f
The
[DIGITAL LINK STATUS]
screen is displayed.
[LINK STATUS]
One of [NO LINK], [DIGITAL LINK], [LONG REACH], or [ETHERNET] is displayed.
[HDCP STATUS]
One of [NO SIGNAL], [OFF], or [ON] is displayed.
[SIGNAL QUALITY]
[SIGNAL QUALITY] is a numerical value of the amount of error, and the display color changes to
green, yellow, or red depending on that value.
Check the signal quality level while receiving a signal from the twisted-pair-cable transmitter.
f
[MAX]/[MIN]: Maximum/minimum value of the amount of error
f
Green (-12 dB or lower)
→
normal signal quality level.
f
Yellow (-11 to -8 dB)
→
caution level that noise may appear on the screen.
f
Red (-7 dB or higher)
→
abnormal level with interrupted synchronization and receiving not
possible.
[DIGITAL LINK MENU]
When the optional DIGITAL LINK output supported device (Model No.: ET-YFB100G, ET-YFB200G) is connected
to the <DIGITAL LINK/LAN> terminal, the main menu of the connected DIGITAL LINK output supported device is
displayed. Refer to the Operating Instructions of the DIGITAL LINK output supported device for details.
Note
f
[DIGITAL LINK MENU] cannot be selected when the [NETWORK] menu
→
[DIGITAL LINK]
→
[EXTRON XTP] is set to [ON].
[EXTRON XTP]
Make connection setting for the "XTP transmitter" of Extron Electronics.
1) Press
as
to select [DIGITAL LINK].
2) Press the <ENTER> button.
f
The
[DIGITAL LINK]
screen is displayed.
3) Press
as
to select [EXTRON XTP].
4) Press
qw
to switch the item.
f
The items will switch each time you press the button.
Содержание DLP PT-FRZ50
Страница 38: ...38 ENGLISH Chapter 3 Basic Operations This chapter describes basic operations to start with ...
Страница 130: ...130 ENGLISH Chapter 5 Operations This chapter describes how to use each function ...
Страница 167: ...ENGLISH 167 Chapter 7 Appendix This chapter describes specifications and after sales service for the projector ...
Страница 188: ...Index 188 ENGLISH WAVEFORM MONITOR 92 Web control 134 WHITE GAIN 65 WIRED LAN 122 Z ZOOM 70 ...