file:///C|/U
...LLSVC_DSC1703003CE/viewing/SGML_VIEW_DATA/ALL/DC-GH5P/SVC/DSC1703003CE/doc/DSC1703003CE_10.xml[11/12/2018 4:48:55 PM]
When remove the fange back adjustment screw, please don’t reuse it. Use new one.
[Abstract of “Simplicity fange back adjustment”]
Set the camera in front of the chart and set center of the chart picture on LCD.
When execute software, camera works AF on 5 spots automatically.
Calculate fange back value at 5 spots and display on PC screen.
Adjust fange back value within the specifcation by the 3 screws.
The details are refer to adjustment manual in adjustment software.
The image sensor of this camera cannot be fxed when power is OFF.
That is why, image sensor adjustment have to do power ON after assembly (state of above).
Stand-alone mount part cannot adjust.
*3 NOTE: (When exchange the Shutter Unit)
After replacing the shutter unit, the shutter unit data has to be stored to the Flash-ROM (IC2003) on the Main P.C.B..
The shutter unit supplied as service parts has affx the label of own confgure data.
By inputting second line to third line of these data into the adjustment software and writing these data to Flash-ROM (IC2003),
the shutter adjustment becomes needless.
In addition, the adjustment software can read data encoded to QR Code by using WEB camera with a close-up function.
After that, proceed the main body adjustment.
The details are refer to adjustment manual in adjustment software.
*4 NOTE: (When exchange the Main P.C.B. and/or Flash-ROM (IC2003))
After exchanging the “Main P.C.B. and/or Flash-ROM”, frst, execute “Initial Settings” to determine the model suffx,
and then, cancel the “Initial Settings” and proceed the adjustments.
When the adjustment data is rewrite without “Initial Settings” execution, may not be able to choose desire model suffx.
During the “Initial Settings” (When the model suffx select screen is displayed), do not power off or do not remove the battery.
* Power down during “Initial Settings” may cause not be able to choose desire model suffx.