![Panasonic AK-UB300G Скачать руководство пользователя страница 84](http://html.mh-extra.com/html/panasonic/ak-ub300g/ak-ub300g_operating-instructions-manual_259135084.webp)
– 84 –
Chapter 6 Web Screen — [Setup] screen
Item
Description of settings
[IP address]
Enter the IP address of the camera to display in the multi-screen. Maximum of four groups with four
cameras in each group (16 cameras) can be registered.
Enter as follows when the HTTP port number of the camera to display is changed.
(Example) 192.168.0.40:8080
f
Factory setting: [selfcamera] ([Cam1]), no registration ([Cam2] to [Cam16])
@
@
NOTE
t
[IP address] is set with this unit for the camera displaying [selfcamera] as the IP address.
[Camera title]
Enter the title of the camera. Entered title of the camera is displayed in the multi-screen screen.
You can enter 0 to 20 single-byte characters.
f
Factory setting: parts No. display ([Cam1]), blank ([Cam2] to [Cam16])
Characters that can be used
f
Single-byte numbers:
0123456789
f
Single-byte alphabet (upper/lower case):
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
f
Single-byte symbols:
!#$%'()*+,-./:;<=>?@[]^_`{|}~\
@
@
NOTE
t
Only part of the camera title may display when 16 screen multi-screen is selected.
t
Display of the multi-screen will be 4:3.
[User mng.] screen
The [User mng.] screen performs the authentication registration to limit the user or computer (IP address) that can access this unit from a computer.
The [User mng.] screen consists of the [User auth.] tab and [Host auth.] tab.
[User auth.] tab
Performs the authentication registration to limit the user that can access this unit from a computer.
A maximum of 24 users can be registered.
@
@
NOTE
t
When authentication of a computer with an identical IP address has been failed eight times or more in 30 seconds (authentication error), the camera
cannot be accessed for a while.
Item
Description of settings
[User auth.]
Sets whether to authenticate users.
[On]:
Authenticates the users.
[Off]:
Does not authenticate the users.
f
Factory setting: [Off]
[Authentication]
Sets the authentication method to be used for user authentication.
[Digest or Basic]:
Uses Digest authentication or Basic authentication.
[Digest]:
Uses Digest authentication.
[Basic]:
Uses Basic authentication.
The UB300 Setting Tool cannot be connected to the camera when [Digest] is selected for [Authentication]
and [User auth.] is set to [On].
f
Factory setting: [Digest or Basic]
[User name]
Enter a user name.
Number of characters that can be entered: 1 to 32
Characters that cannot be entered: Double-byte and single-byte symbols " & : ; \
Entering a user name that has been already registered and clicking the [Set] button overwrites the user
information.
Содержание AK-UB300G
Страница 8: ...Before using the camera read this chapter Chapter 1 Overview ...
Страница 17: ... 17 Chapter 2 Description of Parts Left side Left side 1 1 mark Indicates the imaging plane inside the camera ...
Страница 22: ...This chapter describes the operation of this camera Chapter 3 Operation ...
Страница 68: ...This chapter describes how to configure the settings from a computer Chapter 6 Web Screen ...
Страница 97: ...This chapter describes the warning displays and after sales services of the camera Chapter 8 Maintenance ...
Страница 104: ...This chapter describes the specifications of this product Chapter 9 Specifications ...