INF-6
11
4. LITHIUM BATTERY
4-1. Replacement Procedure
1.
There is a Lithium battery on the BACK CONNECT C.B.A.
2.
Unsolder the Lithium battery and then replace with the new one. Please refer to item
“16. Removal of BACK
CONNECT C.B.A.”
in section 2(Disassembly Procedure) about how removal of BACK CONNECT C.B.A..
NOTE:
The lithium battery is a critical component.
It must never be subjected to excessive heat of discharge.
It must therefore only be fitted in equipment designed specifically for its use.
Replacement batteries must be of the same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts
observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the equipment manufacturer.
Discard used batteries according to manufacture’s instructions.
BACK CONNECT C.B.A.
LITHIUM BATTERY
IC2002<3>
(REAL TIME CLOCK)
RTC_3V
60B
60A
P2002 P53
BACK_CONNECT C.B.A.
VTR C.B.A.
(LI-BATT)
B51