INF-13
5-2-2. Other item.
5-3. ADJUST MENU (VCR mode)
NOTE: Please do not change the setting of the items of “DEBUG DISP” and “DEBUG MODE”. These items
are for factory use only.
DIAGNOSTIC MENU
BER DISPLAY OFF
SAMPLE SPEED SLOW
DIF INFO OFF
CYLINDER 10000H
TAPE RUN 10000H
THREADING 10000T
PUSH MENU TO EXIT
These items are displayed even by the CAMERA
SERVICE menu. (refer to item 5-1-3 and 5-1-5. )
ADJUST MENU
ATF GAIN OFF
LINEARITY OFF
AUDIO FILTER ON
Y LEVEL 1B
C LEVEL 27
DEBUG DISP OFF
DEBUG MODE OFF
LCD OFFSET OFF
PUSH MENU TO EXIT
Setting item for LISTA Measurement
These items are displayed even by
the CAMERA SERVICE menu.
(refer to item 5-1-1 and 5-1-4. )
ADJUST MENU
EVF OFFSET OFF
PUSH MENU TO EXIT
These items are displayed even by
the CAMERA SERVICE menu.
(refer to item 5-1-6. )