[Parameter P76: Setting of no arrival signal select]
䋪
Factory setting data = [0]
Data
setting
Valid
0
1
2
Invalid
Function and details
OPEN arrival signal CLOSE arrival signal
Valid
Valid
Invalid
Invalid
Fault detection of arrival signal
En3
Can be detected Can be detected Can be detected
Can be detected
Can be detected
Can be detected
En4
En5
Cannot be detected
Cannot be detected
Cannot be detected
Note1) When using door control SW mode ( Parameter P09= "4, 5"), the setting
of parameter P76 is invalid while arrival signal is required.
Note2) If there is no arrival signal, fault of no OPEN/CLOSE arrival signal ( En4, En5)
cannot be detected.
(En3: OPEN/CLOSE arrival signal are both turned ON.;
En4: There is no OPEN arrival signal.; En5: There is no CLOSE arrival signal.; )
[Parameter P77: Slip arrival judgment frequency setting]
Data setting range (Hz) 0.1 to 10
䋪
Used to set slip arrival judgment frequency.
When the detection frequency calculated according to encoder signal is less than
slip arrival judgment frequency (setting value), slip arrival is judged.
䋪
If the power supply is turned ON or slip arrival judgment fault operation occurs
when door width is measured, decrease the setting value of parameter P77.
[Parameter P78: Slip arrival judgment time setting]
Data setting range (ms)
Data setting range (ms)
1 to 999
䋪
Used to set the slip arrival judgment time.
䋪
If slip arrival judgment fault operation occurs when the inverter is being started
(door OPEN operation) and being changed between OPEN operation and CLOSE
operation (from OPEN operation to CLOSE operation or from CLOSE operation
to OPEN operation), increase the setting value of parameter P78.
[Parameter P79: Setting of slip OPEN arrival substitute select]
0
g
0.1 to 10( "0" indicates that there is no data change.)
䋪
When the slip of detection OPEN operation arrives, door position data can be selected
to be changed or not to be changed into door width setting value.(parameter d01).
Used to set the time from detection slip arrival to changed data.
䋪
When the setting data value is "0", data will not be changed.
䋪
From detection to arrival of arrival signal, the position data of the door is changed
but is not related with the setting value of parameter P79.
64
No OPEN/CLOSE arrival signal (Parameter P76="2").
Obstacle occurs when power supply is turned ON or when door width is being
measured. Then, the position is judged as CLOSE arrival position. In this case,
the door fails to be controlled normally.
During setting, ensure that the obstacle detection shall be detected before slip
arrival judgment.
When measuring the door width, avoid the occurence of obstacle.
In normal door control, arrival position is judged depending on the door position data.
So the door operates normally.