![Panasonic AAD03011 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/panasonic/aad03011/aad03011_instruction-manual_262786020.webp)
Control Circuit Wiring
䂓
Wiring (Control Circuit Terminal)
䂹
Built-in power supply specification: 12 V DC -10%/ +20%, 0.1A or less
To meet requirements of European standard directive, please refer to
precautions on Page 98.
䂹
Relay output contact specifications:
1c no-voltage contact, 230 V AC 0.3 A, 30 V DC 0.3 A(resistance load)
Mechanical lifetime: 100 million times or more(switching frequency: 180 times/min.)
Electrical lifetime: 100 thousand times or more(switching frequency at rated
control capacity: 20 times/min.)
Note1) Do not use the Built-in power supply for other devices except for the
encoder power supply. The inverter could be damaged if the
Built-in
power supply is connected incorrectly.
Note2) The NPN open collector output should be used for the output signals
(phase A and phase B) of the encoder. Please read the precautions
on the encoder. (See page 21 and page 22)
Note3) The common terminals(
㽹
and
㽽
) are connected within the inverter.
Do not ground the common terminal.
Open signal
Common
Common
Close signal
Open arrival signal
Close arrival signal
Safety sensor
Open speed change signal
Close speed change signal
Phase A signal
Phase B signal
Built-in power
supply
Built-in power
supply
Input signal
Encoder signal
䂓
Wiring (Output terminals)
Relay 1 output
C1
COM NC NO
B1
A1
C2
COM NC NO
B2
A2
C3
COM NC NO
B3
A3
Relay 2 output
Relay 3 output
18
㽲 㽳 㽴
㽶 㽷 㽸 㽹 㽺
㽼 㽽
䋭
䋫
㽵
㽻
Содержание AAD03011
Страница 2: ......
Страница 14: ...Unit mm Outline Dimensions 2䋭㱢5 Mounting holes 90 100 121 130 126 5 12 ...