MODE
RUN
SET
STOP
䂥
䂯
MODE button
SET button
RUN button
STOP button
䂥㩿
UP) button
䂯㩿
DOWN) button
MODE button
This switch is used to change to each "output frequency,
output current display", "frequency setting, control status
monitor", "rotation direction setting", "function setting" mode,
and to switch the display from the data to mode display.
SET button
The switch is used to change the display between the mode
and data display, and to save the data. In the "Output
frequency, output current display mode", this switch changes
the display between the frequency and current.
䂥㩿
UP) button
This switch is used to change the data or output frequency,
and to set forward run direction when carrying out forward
rotation with the operation panel.
䂯㩿
DOWN) button
This switch is used to change the data or output frequency,
and to set reverse run direction when carrying out reverse
rotation with the operation panel.
䊶
Main display
Hz
STOP button
The switch is used to stop the inverter.
RUN button
The switch is used to start the inverter.
Main display
Handling for the displays of output current, output voltage and internal
DC voltage.
1
˅
The displayed output current, output voltage and internal DC voltage are not
intended for precise measurement. Use this only as a guide value.
(Use a separate measuring instrument when precise values are required.)
2
˅
Especially for the displayed output current, a relatively large value may be
displayed at approx.40% or less of the rated current. (For example, even if there
is no output current, a certain level may be displayed. Note that when the
inverter is stopped, "0.0A" will be displayed.)
15
Explanation of
Operation Panel
The output frequency, output current, line speed, control
status monitor, data for function setting and parameter No.
are displayed.