Precautions regarding Inverter's Protection Function
Various protection functions such as stall prevention, current limit, overcurrent
shut-off are built in the inverter.
These protection functions are used to protect the inverter from the sudden
abnormal conditions in use, so they are not the control functions to be always
used.
Therefore, do not use the applications in which those protection functions
activate in the normal operating conditions.
In some cases, the inverter's life may be shorten, or the inverter may be
damaged.
Always measure the output current, etc. with a measuring instrument, and
check the details of the fault trip memory, and confirm that there is no problem
in the conditions for all the precautions and specifications describled in the
manual when using the inverter.
10
Do not use the inverter for loads other than a three-phase induction
motor.