ABOUT YOUR WATER HEATER
4
MAINS PRESSURE
The water heater is designed for direct connection to the mains water supply. If the mains supply
pressure in your area exceeds that shown on page 47, a pressure limiting valve must be fitted. The
supply pressure should be greater than 140 kPa for the rated flow and performance to be
achieved.
HOW HOT SHOULD THE WATER BE?
The water heater may be installed with one or more user adjustable temperature controllers, which
allow you to choose the most suitable temperature for your hot water needs (refer to “Temperature
Control” on page 10).
If a controller is not installed, the water heater heats the water to the pre-set outlet temperature
setting. The factory pre-set outlet temperature setting:
•
PH-246CWHA series
55°C
Note:
The pre-set outlet temperature setting of this water heater cannot be adjusted by the
householder. The setting can only be adjusted by the installer, or a Paloma Service Agent.
Note:
Australian Standard AS 3498 requires that a water heater provides the means to inhibit the
growth of Legionella bacteria in potable water. When this water heater is used as an in-series
booster for a solar water heater it can satisfy this AS 3498 requirement provided it is energised, the
booster pre-set outlet temperature setting is 70°C, and that a remote temperature controller is not
used.
Warning:
Temperature controllers
must not
be fitted to this water heater if it is installed as an in-
series gas booster with a solar water heater system or if a Water Star water heater is installed
because water at a temperature much higher than the controller setting can be delivered. If a
solar or Water Star water heater has been installed to an existing water heater installation, then all
controllers
must be
disconnected and removed.
If this water heater is installed as part of a solar water heater system, the system can deliver water
at temperatures from 58°C up to 80°C and possibly higher depending upon the model of solar
water heater installed.
maximum Kitchen controller
temperature setting.
maximum recommended supply
temperature to bathrooms and ensuites.
maximum Bathroom controller
temperature setting
minimum Kitchen and Bathroom
controller temperature setting