Содержание PH-246CWHA

Страница 1: ......

Страница 2: ...ll this water heater and ask for your Compliance Certificate Warning Upon completion of the installation and commissioning of the water heater leave this guide with the householder or a responsible of...

Страница 3: ...ry care has been taken to ensure accuracy in preparation of this publication No liability can be accepted for any consequences which may arise as a result of its application CONTENTS HOUSEHOLDER We re...

Страница 4: ...PERATION The water heater operates automatically heating water as it passes through the water heater When a hot tap is opened the gas burners ignite to provide immediate heating of the water The heat...

Страница 5: ...the means to inhibit the growth of Legionella bacteria in potable water When this water heater is used as an in series booster for a solar water heater it can satisfy this AS 3498 requirement provide...

Страница 6: ...touch the power plug with wet hands SAFETY This water heater is supplied with temperature sensors a FlameSafe protection system and a pressure relief valve These devices must not be tampered with or...

Страница 7: ...mended minor maintenance be performed every six months by the dwelling occupant The minor maintenance includes Inspect around the air inlet flue terminal and the water heater in general for plant grow...

Страница 8: ...is on will go out Switch off the electrical supply at the power outlet to the water heater if there is no risk of freezing conditions occurring refer to note below Close the gas isolation valve at the...

Страница 9: ...page 78 If it is necessary to switch the power off to the water heater and there is a risk of freezing then it is necessary to drain the water heater refer to Draining the Water Heater on page 8 Pipe...

Страница 10: ...e pipe work between the solar storage tank if one is installed and the in series gas booster has a minimum recommended pipe size of DN20 MUST BE of copper and be fully insulated in accordance with the...

Страница 11: ...esigned to allow the water heater to deliver a selected volume of water at a selected temperature Bath filling takes place when the hot tap is opened When the set volume has been delivered the water f...

Страница 12: ...r they are on or off when hot water is flowing regardless of which controller has priority display panel The current temperature setting is displayed on all controllers whether hot water is flowing or...

Страница 13: ...on off button to deactivate the controller on off light is off Press and hold the up button Press the on off button whilst the up button is pressed The sound for the controller is deactivated Repeat...

Страница 14: ...efaults to the pre set outlet temperature setting This may be up to PH 246CWHA series 60 C Refer to How Hot Should The Water Be on page 4 On a building fitted with a temperature limiting device such a...

Страница 15: ...l scroll the temperature setting up to a maximum 43 C if there is hot water flowing or 55 C if there is no hot water flowing From the 45 C setting the up button must be pressed once for each increase...

Страница 16: ...ority if a Bathroom controller is on Notes on the Kitchen controller The controller cannot be turned on whilst a hot tap is open The Kitchen controller must be on and have priority in order to adjust...

Страница 17: ...e Adjustment Standard Controller on page 14 The selected temperature setting will be displayed on all controllers 4 Open the hot tap The in use light will glow on all controllers 5 Close the hot tap T...

Страница 18: ...re limiting device is installed in the hot pipe to the bathroom or up to 55 C if a temperature limiting device is not installed Notes on the Bathroom controllers The controller cannot be turned on whi...

Страница 19: ...he Bathroom controller Press the on off button The on off operating light and the priority light will both glow The temperature setting of 40 C will be displayed 3 Select the temperature setting Press...

Страница 20: ...r down button will change the water volume setting by 10 litres Pressing the up button or down button continuously will scroll the water volume setting Fifteen seconds after the water volume has been...

Страница 21: ...troller on page 12 The factory pre set water volume is 180 litres If a hot tap is not opened for one hour after the new water volume has been set then the setting will be automatically cancelled The w...

Страница 22: ...xe controllers whether hot water is flowing or not when any Deluxe controller is on If all Deluxe controllers are off the display remains blank up button The up button increases the water temperature...

Страница 23: ...BATH FILL VOLUME up button The up button increases the bath fill water volume setting in increments of 10 litres up to 500 litres A further setting of 990 litres can be selected BATH FILL VOLUME down...

Страница 24: ...rom the water heater during Bath Fill mode the bath is ready please turn off the hot water tap and press the BATH FILL button to finish When the BATH FILL button is pressed to halt the bath fill funct...

Страница 25: ...utton then within four 4 seconds press the ON OFF button Each press of the ON OFF button will change the voice prompt and operating tone in the following sequence operating tone MAX voice prompt OFF o...

Страница 26: ...talled the water heater defaults to the pre set outlet temperature setting This may be up to PH 246CWHA series 60 C Refer to How Hot Should The Water Be on page 4 On a building fitted with a temperatu...

Страница 27: ...45 C if there is no hot water flowing From the 45 C setting the up button must be pressed once for each increase in temperature increment The temperature setting cannot be increased above 43 C whilst...

Страница 28: ...e Deluxe controller cannot be turned on whilst a hot tap is open The Kitchen Deluxe controller must be on and have priority ACTIVE light glows in order to adjust the temperature setting on the Kitchen...

Страница 29: ...e has been decreased Refer to Temperature Adjustment Deluxe Controllers on page 26 The selected temperature setting will be displayed on all Deluxe controllers 4 Open the hot tap The operating light w...

Страница 30: ...room Deluxe controller must be on in order to adjust the temperature setting on the Bathroom Deluxe controller The Kitchen Deluxe controller can be turned off from a Bathroom Deluxe controller Press a...

Страница 31: ...has been increased When the down button is pressed the voice prompt will sound hot water temperature has been decreased Refer to Temperature Adjustment Deluxe Controllers on page 26 The selected temp...

Страница 32: ...rs It is advised to turn off all Deluxe controller s before activating the Bath Fill mode Refer to the notes on the Bathroom Deluxe controllers on page 29 2 Pull down the front panel on the Deluxe con...

Страница 33: ...The temperature display will go blank The BATH FILL operating light will commence to flash The voice prompt will sound the bath is ready please turn off the hot water tap and press the BATH FILL butt...

Страница 34: ...on is pressed and the temperature setting is decreased the voice prompt will sound hot water temperature has been decreased The selected temperature setting will be displayed in the temperature displa...

Страница 35: ...t will glow on all Deluxe controllers The bath fill water volume display panel will go blank and the bath fill indicator light will go out 3 seconds after the last press of either of the volume adjust...

Страница 36: ...bath fill water volume display panel will show 0 litres The temperature display will go blank The BATH FILL operating light will commence to flash The voice prompt will sound the bath is ready please...

Страница 37: ...ight will flash The voice prompt will sound bath filling has been stopped please turn off the hot water tap and press the BATH FILL button to finish Close the hot tap Press the BATH FILL button again...

Страница 38: ...the Bath Fill mode is turned on If the ACTIVE light is glowing on a Deluxe controller it will go out The ACTIVE light on a Deluxe controller will not glow whenever the BATH Fill operating light is on...

Страница 39: ...on the bath fill operation continues until the remaining bath fill water volume is consumed then The water flow will cease and the voice prompt will sound the bath is ready please turn off the hot wa...

Страница 40: ...The bath fill temperature setting will replace the temperature setting in the temperature display panel When the bath fill temperature setting is lower than the Deluxe controller temperature setting...

Страница 41: ...nwater tank supply bore water supply desalinated water supply public reticulated water supply or water brought in from another supply then water chemistry information should be sought from the supplie...

Страница 42: ...41...

Страница 43: ...outlet switched on Is power available in the house Try using another electrical appliance Is the isolation valve in the gas line open Is there a gas supply to the rest of the house Try lighting anoth...

Страница 44: ...ess of the solar collectors will be greatly reduced Have the trees trimmed or the solar collectors relocated if the obstruction is permanent or clean the collector glass Ensure the glass on your solar...

Страница 45: ...ue If an error code appears Close the hot tap turn off the controller s and switch off the electrical supply to the water heater Check the gas isolation valve at the gas inlet to the water heater is f...

Страница 46: ...redundancy into the hot water supply system The PH 246CWHA series water heater may be installed as an in series gas booster to a solar water heater For information relating to the function and operati...

Страница 47: ...ns Standard The distances are measured along the wall behind the water heater At least 300 mm between the top of the flue terminal and the eaves At least 300 mm between the flue terminal and the edge...

Страница 48: ...water heater must be insulated with suitable thickness insulation if freezing conditions are likely to occur The insulation must be fitted to the underside of the water heater and be weatherproof and...

Страница 49: ...water heater the cold water line to the temperature limiting device can be branched off the cold water line either before or after the isolation valve and pressure limiting valve to the water heater...

Страница 50: ...gher water temperatures generated under certain conditions in the solar collectors of an open circuit direct solar water heater an additional effective back flow prevention device also should be used...

Страница 51: ...ed The circulator must not be set to operate continuously i e 24 hours per day Temperature Limiting Device A temperature limiting device cannot be installed in circulated hot water flow and return pip...

Страница 52: ...The hot water line from the water heater and the pipe work between the solar storage tank if one is installed and the in series gas booster must be insulated in accordance with the requirements of AS...

Страница 53: ...utlet temperature is 55 C Kitchen Controller Only Bathroom Controllers Only Note The maximum outlet temperature is 55 C in a domestic situation The maximum programmable temperature is 60 C No Controll...

Страница 54: ...in 24 Mass Empty unpackaged kg 19 Gas Details Hourly Gas Consumption MJ Min Gas Pressure kPa Test Point Gas Pressure kPa Max Gas Pressure kPa minimum maximum Natural 188 1 13 0 20 0 83 3 50 LPG 188 2...

Страница 55: ...INSTALLATION WATER HEATER 54 DIMENSIONS STANDARD CONTROLLERS Kitchen Controller Standard Bathroom Controller Standard...

Страница 56: ...INSTALLATION WATER HEATER 55 DIMENSIONS DELUXE CONTROLLERS Deluxe Controller Cover Closed Deluxe Controller Cover Open...

Страница 57: ...INSTALLATION WATER HEATER 56 TYPICAL INSTALLATION OUTDOOR LOCATION...

Страница 58: ...ust not be installed An acceptable arrangement is shown in the diagram Refer also to Hot Water Delivery on page 48 and to Mains Water Supply on page 47 A disconnection union must always be provided at...

Страница 59: ...to the connections on both the solar storage tank and the in series gas booster A full flow isolation valve must be installed on the water line to the in series gas booster GAS INLET The gas connecti...

Страница 60: ...s been installed to an existing water heater installation then all controllers must be disconnected and removed The water heater is supplied with a 1 8 metre lead and plug and requires a weatherproof...

Страница 61: ...K 2B or the Bathroom controller cable Paloma K 2C Notes Where more than one controller is installed the second or third controller must be of the same family A standard controller can only be install...

Страница 62: ...he controllers are not weatherproof KITCHEN CONTROLLER The standard Kitchen controller Paloma MC 101 or Kitchen Deluxe controller Paloma MC 115 is to be installed in the kitchen or laundry only It has...

Страница 63: ...ds 6 Connect the cable to the two terminals on the back of the controller connections are not polarity sensitive Ensure the connecting screws are seated tightly 7 Place the controller over the base pl...

Страница 64: ...1 and 4 and make an opening in the thin section in the underside of the controller to accommodate the cable as shown in the diagram prior to Step 6 Kitchen Controller Standard and Deluxe Installation...

Страница 65: ...setting of PH 246CWHA series 50 C The method of installation for the standard Bathroom1 and Bathroom2 controllers and the Bathroom1 Deluxe and Bathroom2 Deluxe controllers is identical Choose a suitab...

Страница 66: ...the base plate 7 Fix the base plate to the wall using suitable screws and wall anchors Ensure the projections in the base plate are pointing upwards 8 Plug the controller wire into the Bathroom contr...

Страница 67: ...It is important to seat the cables into the cable notches Failure to do this may cause an unstable contact or even disconnection of the cables from the terminals if the cables were to be pulled 6 Ref...

Страница 68: ...rporated in the water heater is not adjustable To complete the installation it is necessary to check the gas supply pressure at the inlet to the water heater refer to Gas Inlet Pressure on page 67 the...

Страница 69: ...switched on and turn on a controller if one is fitted by pressing the on off button 7 Open a hot tap fully and ensure the burners are fully ignited It may be necessary to open a second tap 8 Turn on a...

Страница 70: ...e the burner pressure test point on the main burner manifold Remove the test point screw and washer from the test point orifice Connect the manometer 6 Switch on the electrical supply at the power out...

Страница 71: ...e incoming cold water temperature Note In Step 9 4H will be shown on the LED display After setting the minimum and maximum test point gas pressures Close the hot tap Remove the manometer and refit and...

Страница 72: ...the water heater Gas Booster for a Solar Water Heater Note Australian Standard AS 3498 requires that a water heater provides the means to inhibit the growth of Legionella bacteria in potable water Whe...

Страница 73: ...ater 2 Remove the screws holding the front panel to the jacket 3 Gently disengage the front panel and pull forward to remove from the water heater 4 Switch on the electrical supply at the power outlet...

Страница 74: ...tlet temperature compensation adjustment procedure Warnings The removal of the front panel will expose 240 volt wiring Take care not to touch wiring terminals The adjustment must be carried out by a q...

Страница 75: ...ted the maximum outlet temperature of the water heater can be adjusted upwards 5 Turn off the hot tap 6 Switch off the electrical supply at the power outlet to the water heater 7 Remove the screws hol...

Страница 76: ...ontroller s to the Water Heater on page 66 16 Refit the front panel and screws to the water heater 17 Switch on the electrical supply at the power outlet to the water heater TO TURN OFF THE WATER HEAT...

Страница 77: ...y the shower outlet Unscrew the two drain plugs one each at the cold water inlet and hot water outlet on the underside of the water heater Water will drain from the water heater When water stops flowi...

Страница 78: ...in information from your local water supply authority plumber or merchant This water heater is not suitable for connection to bore spring or rain water unless a water treatment device is fitted to buf...

Страница 79: ...on in the waterways of a water heater with a frost protection system due to an ambient temperature below 20 C including wind chill factor ice formation in the water ways of a water heater where the wa...

Страница 80: ...Revision Date 2013 January 31 76787 00 79...