TROUBLESHOOTING GUIDE
The Interface Control Screen will show error notices when
machine malfunctions occur. They will display the probable
causes and possible remedies. Follow the remedies to resolve
the problem and press reset button to remove the Error Notice.
The diagram on the left shows a map with numbers identifying
the location of various malfunctions.
Location of Malfunction
Possible Cause(s)
Corrective Action
7
4
5
2
8
3
6
9
1
1. Abnormal forward limit switch
1. Check forward limit switch
2. No material in the shuttle vise
1. Check material in the
shuttle vise
3. Abnormal rotary encoder
1. Check rotary encoder wires
2. Check rotary encoder
function
4. Abnormal shuttle-vise pressure
sensor
1. Check shuttle vise pressure
sensor function
5. Abnormal bench-vise pressure
sensor
1. Check bench vise pressure
sensor function
6. Abnormal blade tension
1. Check for broken blade
2. Check for blade tension
3. Check blade sensor
7. Abnormal probe arm limit switch
1. Check probe arm limit switch
2. Check probe arm sliding
function
8. Abnormal bow down limit switch
1. Check bow down limit switch
9. Blade cover opened
1. Check blade cover limit
switch
2. Close blade cover
10. Abnormal motor inverter
1. Check motor inverter
11. Abnormal blade motor blade
motor
1. Check overload relay of
blade motor
12. Abnormal hydraulic motor
1. Check overload relay of
hydraulic motor
13. Abnormal coolant motor
1. Check overload relay of
coolant motor
14. Emergency button locked
1. Rotate and release
Emergency button