8
Getting st
ar
ted
Installation
Leak test:
1. Brush or spray soapy solution onto all connections shown (see image A).
2. Slowly open LP cylinder shut-off valve by turning hand wheel counterclockwise, while checking for bubbles.
3. If “growing” bubbles appear, there is a leak.
a. If the leak is at the cylinder (see image B), turn cylinder shut-off valve clockwise to the “CLOSED” position. DO NOT OPERATE THE
BARBECUE. Disconnect the cylinder and return the cylinder to your local retailer.
b. If the leak is at the regulator or manifold connections (see image C), turn cylinder shut-off valve clockwise to the “CLOSED” position.
Re-tighten connections and repeat steps 1 and 2.
c. If leaks cannot be stopped do not try to repair. Call for replacement parts. Order new parts by contacting Vida by PADERNO™
Customer support 1-800-263-9768.
4. If bubbles do not appear, leak check is complete. Turn the LP cylinder shut-off valve clockwise to close.
NOTE: SOME LEAK TEST SOLUTIONS MAY BE SLIGHTLY CORROSIVE. ALL CONNECTIONS SHOULD BE RINSED WITH WATER AFTER CHECKING FOR LEAKS.
Regulator flow limiting device activated (propane models)
If you are experiencing any of the following performance issues, you may have activated the flow limiting feature in your regulator:
•
Burners not getting hot enough.
•
Low or incomplete burner flames.
•
Low gas pressure.
•
Difficulty lighting all burners or burners not staying lit.
CAUTION: IF YOU HEAR A RUSHING SOUND, TURN GAS OFF IMMEDIATELY. THERE IS A LEAK AT THE CONNECTION. CORRECT
BEFORE PROCEEDING.
CAUTION: A FROSTY REGULATOR INDICATES GAS OVERFILL. IMMEDIATELY CLOSE LP CYLINDER VALVE AND CALL LOCAL LP GAS
DEALER FOR ASSISTANCE.
WARNING: DO NOT SMOKE DURING LEAK TEST.
DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
BARBECUE MUST BE LEAK TESTED OUTDOORS IN A WELL-VENTILATED AREA, AWAY FROM IGNITION SOURCES. DURING LEAK TEST,
KEEP YOUR BARBECUE AWAY FROM OPEN FLAMES OR SPARKS.
CAUTION: IF IT IS EVIDENT THERE IS EXCESSIVE ABRASION OR WEAR OR THE HOSE IS CUT, IT MUST BE REPLACED PRIOR TO THE
BARBECUE BEING PUT INTO OPERATION. THE REPLACEMENT HOSE ASSEMBLY SHALL BE THAT SPECIFIED BY THE MANUFACTURER.