6
Getting st
ar
ted
Installation
Important information about LP gas & regulator connections
What is liquid petroleum (LP) gas?
Liquefied petroleum gas, also called LP gas, liquid propane or propane is non-toxic, odourless and
colourless when produced. For your safety, LP gas has been given an odour (similar to rotten cabbage) so
that it can be detected.
LP gas is highly flammable and may ignite unexpectedly when mixed with air.
LP Cylinder inspection
1. Confirm that the cylinder shut-off valve is fully closed, by turning clockwise (see image A).
2. Confirm that the cylinder valve is the proper Type 1 mating (see image B).
3. Inspect the cylinder valve, including the internal rubber seal for damage or debris (see image C).
If damaged, return cylinder to local retailer.
LP CYLINDER VALVE REQUIREMENTS:
LP gas supply cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of
the Canadian Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Commission, CAN/
CSA-B339; or LP gas Cylinders of the U.S. Department of Transportation (D.O.T), as applicable.
Propane Cylinder must not exceed 20 lb (9.1 kg) capacity, approximately 18¼ inches (46.35 cm) high and
12¼ inches (31.1 cm) in diameter. The LPG capacity is approximately 47 lb 10 oz (21.6 kg) water capacity or as stated by the
manufacturer.
Shut-off valve with a correct cylinder valve output as specified in current standards. ANS Z21.58-2018/CSA1.6-2018 Outdoor
Cooking Gas Appliances.
Type-1 mating (CGA 810) compatible with this barbecue. The type 1 valve is easily recognized by the large ACME external
threads on the outside of the valve.
Safety relief valve with direct connection to the vapour space of the cylinder.
UL listed Overfill Protection Device (OPD). This OPD safety feature is identified by a unique triangular hand wheel. Use only
LP cylinders equipped with this type of valve.
A device for vapour withdrawal.
A collar to protect the LP cylinder shut-off valve.
A ring on the bottom of the LP cylinder to secure it to the support assembly.
Equipped with a dust cap for the cylinder valve outlet, which must be used whenever the cylinder is not in use.
Cylinders must have a D.O.T. certification (A) and a testing date (B) that is within five years of current use.
B
C