SECTION 4
OPERATION
41
4.3.2 VOLTAGE ENTRY
To achieve MANUAL MODE and change voltage, from any meter display light the Va, Vb, Vc LEDs by
pressing those keys.
Pressing an ARROW key causes selected voltages to slew up or down. Entering a number then
pressing
EXECUTE
causes selected voltages to change to new values. The upper right corner of the
display shows the last entered voltage.
For example to change to 125 volts, light Va, Vb and Vc LEDs as desired by pressing their keys. Enter
125
and press
EXECUTE
. The Power Source should now be generating 125 volts.
V/I METER: ENTRY: 125.0
FREQ=60.00 Va=125.0 Vb=125.0 Vc=125.0
SENSE=INT Vab=216.5 Vbc=216.5 Vca=216.5
MANUAL MODE Ia=00.0 Ib=00.0 Ic=00.0
4.3.3 FREQUENCY CONTROL
To achieve MANUAL MODE and change frequency, from any meter display light the F LED by pressing
that key.
Pressing an ARROW key causes the frequency to slew up or down. Entering a number then pressing
EXECUTE
causes the frequency to change to the new value. The upper right corner of the display
shows the last entered frequency.
For example to change to 60.50 Hz. light the F LED: enter
60.50
and press
EXECUTE
. The Power
Source should now be generating 60.50 Hz..
V/I METER: ENTRY: 60.50
FREQ=60.50 Va=120.0 Vb=120.0 Vc=120.0
SENSE=INT Vab=208.0 Vbc=208.0 Vca=208.0
MANUAL MODE Ia=00.0 Ib=00.0 Ic=00.0
4.4
PROGRAM OPERATE MODE
This section describes Program Operate Mode.
Program Operate Mode allows pre-stored program execution including transients.
When the V/I METER display is active the lower left corner will indicate the number of the PROGRAM
currently being executed.
Содержание UPC-12
Страница 2: ......
Страница 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Страница 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 32 Figure 1 3b UPC 32 Figure 1 3c UPC 12 ...
Страница 46: ...SECTION 4 OPERATION 34 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Страница 77: ...SECTION 4 OPERATION 65 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Страница 139: ...NOTES 127 NOTES ...
Страница 140: ...MODIFICATIONS 128 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made ...