Page 38
Kore 7th Manual / kHLab Edition
5.2. Connection
Connect
Allows establishing the connection with doser on the choose
COM port nr (this port is assigned to doser during the installation
process).
Disconnect
Close connection/communication with doser.
Refresh all settings
By pressing this button you can
refresh/load
all important doser
settings. It can take up to two-three minutes.
BlueTooth Connection
group box
Active Alarms
group box
Temperature alarm
If that alarm is active it mean that your water temperature is above
or below maximum/minimum settings (check this on
ATO/Temp
config
).
Liquids alarm
(low level)
If active – liquid level (in any container) reached minimum level
(configured in
ATO/Temp config
).
ATO alarm
(no refill)
Active when ATO tried refill four times without success. Check
that your DC pump is working or refill container isn’t empty.
High water level
Your sump water level is too high(above top floating level switch).
It can be also activated by optical sensor working as a safety
sensor (you can set working mode for the optical sensor in the
last
Service
TAB).
pH1 alarm
Active when pH is Lower than
pH#1
set in “pH ports / kHLab
config” TAB.
pH2 alarm
Active when pH is Lower than
pH#2
set in “pH ports / kHLab
config” TAB.
This group box shows all active doser alarms: