SECTION 4
OPERATION
60
4.6.2.1 EDIT WAVEFORM
EDIT WAVEFORM is used to change or modify waveforms.
From any METER display (V/I, AMPS or POWER), press the
fn
key to enter SETUP MODE.
From the SETUP display, press
2
to enter WAVEFORM SETUP.
From the WAVEFORM SETUP display, press
1
to enter EDIT WAVEFORM.
EDIT WAVEFORM: NUMBER=16 RANGE=2-22
STARTING PHASE ANGLE =0 0-359.9º
ENDING PHASE ANGLE =0 0-359.9º
VOLTAGE IN PERCENT =-100 (+/-)0-100%
Press
EXECUTE
to save a new waveform.
The UPC will stop generating any output while the new waveform is being calculated.
NUMBER:
Waveforms
number
2-22
may be edited.
(waveform 1 is always a sine wave)
PHASE ANGLE:
The STARTING AND ENDING PHASE ANGLE determine what portion
of the waveform is being edited.
VOLTAGE IN PERCENT:
All points on the waveform between the starting and ending phase
angle defined above will change to this new amplitude. Enter the
amplitude as a percent, relative to the peak of the waveform, either
positive or negative.
The UPC will attempt to generate the selected waveform at the rms voltage programmed. Because of
the difference in the rms voltage content of various waveforms the UPC may not be able to reproduce
the waveform at the voltage desired. If the waveform is peak-voltage-limiting, then selecting transformer
coupled output with a higher ratio may solve this problem.
Basic sinusoidal waveforms with large dropouts or spikes will change the rms content of the waveform.
Depending on the TRANSIENT WFs setting, the UPC may cause the basic sine wave to change in
amplitude in order to keep the correct rms voltage. If you wish to keep the basic sine wave at the same
amplitude and add a large dropout, you must program a proportionally lower rms voltage or DISABLE the
RMS calculation. If you wish to keep the basic sine wave at the same amplitude and add a large spike,
you must program a proportionally larger rms voltage.
EXAMPLE: To put a 10% spike on top of a sine wave, first copy waveform 1 to waveform 2 at a 90%
amplitude scale factor to allow 10% more voltage at the peak of the sine wave to accommodate the
spike.. See the example in section 4.6.2.2, Copy Waveform.
From the WAVEFORM SETUP display, press
1,
to enter EDIT WAVEFORM.
EDIT WAVEFORM: NUMBER =2 RANGE=2-22
STARTING PHASE ANGLE =0 0-359.9º
ENDING PHASE ANGLE =0 0-359.9º
VOLTAGE IN PERCENT =-100 (+/-)0-100%
Содержание UPC-3
Страница 1: ...UPC 3 UPC 1 PROGRAMMABLE CONTROLLERS FIRMWARE V4 25 AND LATER OPERATION MANUAL PACIFIC POWER SOURCE δ ...
Страница 2: ......
Страница 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Страница 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Страница 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Страница 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Страница 134: ...NOTES 122 NOTES ...
Страница 135: ...MODIFCATIONS 123 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made ...