SECTION 4
OPERATION
27
SECTION 4
FRONT PANEL OPERATION
4
FRONT PANEL OPERATION
This section describes the front panel operation of an UPC Controller installed a power source. The
UPC controllers are used with Pacific Power Source, Inc’s AMX, ASX, G, and MS series equipment.
The UPC Controller allows the user to control all output parameters of the power source via the front
panel keyboard as well as through the REMOTE interface (see Section 5 for REMOTE operation).
4.1
GUIDE TO QUICK OPERATION
These instructions will:
1. present
a
QUICK OVERVIEW
of UPC operation (para. 4.1.1),
2. help
in
QUICKLY PUTTING THE UNIT TO USE
for basic operation, without having to
master all of its complexities (para. 4.1.2).
4.1.1 QUICK OVERVIEW
The information contained in this section is necessary for use of the UPC controller. In addition to quick
usage, this section describes basic operational characteristics that are essential when studying UPC
operation in depth.
The UPC is operable either from its front panel keyboard (LOCAL CONTROL operation) or by its Data
Bus (REMOTE CONTROL operation, RS-232 serial or IEEE-488/GPIB). A host computer can force
REMOTE CONTROL when the UPC is displaying a Metering display. LOCAL CONTROL can be
resumed either by a bus command (GoTo Local) or by manually pressing the
LOCAL
key. The host
computer can force retention of REMOTE CONTROL by issuing a lockout command (Local LockOut
(LLO), para. 5.6.1), thereby preventing manual override.
When using the UPC controller, it is useful to think of it as being in one of 4 operating "modes" when in
LOCAL CONTROL.
1. MANUAL
OPERATE
2. PROGRAM
OPERATE
3. PROGRAM
EDIT
4. SETUP
MANUAL MODE is control of the operating characteristics via the front panel keyboard. Voltage and
Frequency parameters are manually set from the front panel. Volts and Frequency may be directly
entered through the numeric keyboard or they may be smoothly varied by use of the "slew" controls (up
and down arrows). The V/I METER display (default display) shows both command values and metered
values. Stored transients may not be executed in the MANUAL MODE.
The UPC-3M and UPC-1M manual version controllers operate ONLY in the MANUAL MODE.
Содержание UPC-3
Страница 1: ...UPC 3 UPC 1 PROGRAMMABLE CONTROLLERS FIRMWARE V4 25 AND LATER OPERATION MANUAL PACIFIC POWER SOURCE δ ...
Страница 2: ......
Страница 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Страница 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Страница 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Страница 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Страница 134: ...NOTES 122 NOTES ...
Страница 135: ...MODIFCATIONS 123 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made ...