![Pacific Power Source UPC-3 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/pacific-power-source/upc-3/upc-3_operation-manual_3150600042.webp)
SECTION 4
OPERATION
30
4.1.2 QUICKLY PUTTING THE UNIT TO USE
The following steps provide a quick method (using MANUAL MODE) for setting Voltage and Frequency
and applying power to a load. To set other parameters, such as phase angle, waveform, current limit,
power form and output coupling mode (transformer or direct), use the PROGRAM EDIT MODE. It also
allows you to setup transient events. Programming and executing a stored program is described in
sections 4.5 and 4.4 respectively. For a list of individual functions, see the
HOW TO
reference in the
beginning of this manual.
QUICK MANUAL MODE OPERATION
NOTE: OBSERVE ALL SAFETY WARNINGS AND CAUTIONS LISTED AT THE START OF THIS
MANUAL !!!
1.
DO NOT CONNECT A LOAD
to the power source until you are satisfied that the power source
output is appropriate for the load.
2.
Be certain that the
OUTPUT POWER SWITCH
is
OFF
. Then apply input power to the UPC or
power source using its INPUT POWER SWITCH. Allow a few seconds for the UPC to initialize.
It will beep twice when it is ready.
3.
The V/I METER will appear. This is the default display. It shows metered Volts and Amps (AC
RMS). It also shows the Voltage and Frequency entries in the upper right corner of the display
as the user is entering or changing them.
4.
TO CHANGE VOLTAGE - Light the
Va
,
Vb
and/or
Vc
LEDs by pressing the keys below them.
Now perform one of the following steps:
A.
Enter a numeric value on the keypad and press
EXECUTE
. - or -
B.
Press the UP or DOWN arrows (
︿
or
﹀
) to 'slew' the voltage.
The phases that are indicated by the V LEDs will be changed to the voltage selected.
5.
TO CHANGE FREQUENCY - Light the
F
LED by pressing the F key. Now perform one of the
following steps:
A.
Enter a numeric value on the keypad and press
EXECUTE
- or-
B.
Press the UP or DOWN arrows to 'slew' the frequency.
NOTE:
You cannot change Voltage and Frequency simultaneously using MANUAL MODE.
6.
TO CLOSE THE OUTPUT RELAY - First switch the
OUTPUT POWER SWITCH
on the power
source front panel to ON/AUTO. Then press the
OUTPUT ENABLE
key on the UPC keyboard.
Verify the power source output (rear panel output terminals) is generating the desired voltage,
frequency and phase angle using an oscilloscope and/or meters.
7.
TO APPLY POWER TO THE LOAD, first
TURN OFF the INPUT POWER
switch,
TURN OFF
the OUTPUT POWER
switch. Connect the load to the rear panel output terminals. Switch ON
the INPUT POWER switch, switch ON the OUTPUT POWER switch. Then press the
OUTPUT
ENABLE
key on the UPC controller. Power is now being applied to the load.
Содержание UPC-3
Страница 1: ...UPC 3 UPC 1 PROGRAMMABLE CONTROLLERS FIRMWARE V4 25 AND LATER OPERATION MANUAL PACIFIC POWER SOURCE δ ...
Страница 2: ......
Страница 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Страница 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Страница 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Страница 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Страница 134: ...NOTES 122 NOTES ...
Страница 135: ...MODIFCATIONS 123 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made ...