SECTION 5
REMOTE OPERATION
98
5.6.2 IEEE-488.2 DEVICE CONTROL COMMANDS
The following lists the IEEE-488.2 Common Commands for
Device Control
of the UPC. Refer to the
ANSI/IEEE-488.2 1987 standard for more information.
*RST
Command: RESET. Initialize the UPC with the following parameters:
CSC OFF
CURRENT LIMIT
CURRENT METERING RANGE
INITIAL VOLTAGE
0
KEYBOARD LOCK
OFF
MAX FREQUENCY
1200 Hz.
MAX VOLTS
600 V
MIN FREQUENCY
15 Hz.
MIN VOLTS
0 V
MODE MANUAL
OUTPUT DISABLED
OUTPUT COUPLING
DIRECT
OUTPUT FORM
1 or 3 (depending on model)
OUTPUT FREQUENCY
60 Hz.
OUTPUT VOLTAGE(S)
0
PHASE ANGLE B
120º
PHASE ANGLE C
240º
PROG.Zo OFF
RANGE CONTROL
AUTO
SENSE INTERNAL
TRANSITION TIME
0
WAVEFORM
Φ
A 1
WAVEFORM
Φ
B 1
WAVEFORM
Φ
C 1
NOTE:
Stored programs are not erased. FREQUENCY SPAN is not changed.
*TST?
Query: Self test. Test validity of non-volatile RAM.
Returns 0 if no error.
*WAI
Command: Wait-to-continue. Only useful following the :PROG:EXEC:TRANS or
*TRG commands. All other commands are executed sequentially as the
Program Message is parsed.
*TRG
Command: IEEE-488.2 Device trigger function. Executes Transient Events (if
any), of currently executed program.
*LLO
Command: LOCAL LOCKOUT. Puts the UPC into REMOTE mode and
disables local operation of the UPC keyboard.
*GTL
Command: GOTO LOCAL. Enables local operation of the UPC keyboard.
*DCL
Command: DEVICE CLEAR. Performs a hardware RESET of the UPC.
Содержание UPC-3
Страница 1: ...UPC 3 UPC 1 PROGRAMMABLE CONTROLLERS FIRMWARE V4 25 AND LATER OPERATION MANUAL PACIFIC POWER SOURCE δ ...
Страница 2: ......
Страница 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Страница 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Страница 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Страница 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Страница 134: ...NOTES 122 NOTES ...
Страница 135: ...MODIFCATIONS 123 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made ...