SECTION 2
SPECIFICATIONS
20
2.4
GPIB REMOTE INTERFACE
The GPIB Remote Interface is provided on J4. It has listener and talker capabilities.
The GPIB device address is set via the UPC STATUS display screen. Default address is 1. See section
4.6.3.3 for configuration and section 5 for programming information.
J4
(Rear of SCU)
DI
01
1
DI
05
13
DI
02
2
DI
06
14
DI
03
3
DI
07
15
DI
04
4
DI
08
16
EOI (End Or Identify)
5
REN (Remote Enable)
17
DAV (DAta Valid)
6
LV
COMMON
18
NRFD (Not Ready For Data)
7
LV
COMMON
19
NDAC (Not Data ACcepted)
8
LV
COMMON
20
IFC (InterFace Clear)
9
LV
COMMON
21
SRQ (Service ReQuest)
10
LV
COMMON
22
ATN
(ATteNtion)
11
LV
COMMON
23
SHEILD
12
LV COMMON (Logic Gnd)
24
Figure 2.4
J4 GPIB REMOTE INTERFACE