SECTION 4
OPERATION
55
4.5.2.2 CYCLE BASED TRANSIENT EXAMPLE (cont)
Press
15, ENTER, 15, ENTER, 15,
to select waveform #15 on all three phases.
TRANSIENT: PRGM #4 SEGMENT #1 OF 1
T=1 CYCLE Va=122 Vb=122 Vc=122
F=400 WFa=15 WFb=15 WFc=15
Press
STORE,
to save the transient sequence.
TRANSIENT EVENTS:
ENTER # OF TRANSIENT EVENTS 1
0 FOR INFINITE OR 1-65535.
Press
1
,
STORE
, to cause only one transient event.
V/I METER:
FREQ=400.0 Va=108.0 Vb=108.0 Vc=108.0
SENSE=INT Vab=187.1 Vbc=187.1 Vca=187.1
MANUAL MODE Ia=00.0 Ib=00.0 Ic=00.0
If the UPC was previously executing program #4, it will now be in MANUAL MODE. This is because
program #4 has changed. To execute the transient you must first execute program #4. Press
PROGRAM, 4, ENTER, EXECUTE,
to execute the program.
V/I METER:
FREQ=400.0 Va=108.0 Vb=108.0 Vc=108.0
SENSE=INT Vab=187.1 Vbc=187.1 Vca=187.1
PROGRAM #4 Ia=00.0 Ib=00.0 Ic=00.0
Press
TRANS
to execute the transient.
This cycle based transient will switch waveform #15 in for one cycle. This will cause a spike on the
positive and negative half of the sine wave for one cycle. See figure 4.5.2.2.
Содержание UPC-3
Страница 1: ...UPC 3 UPC 1 PROGRAMMABLE CONTROLLERS FIRMWARE V4 25 AND LATER OPERATION MANUAL PACIFIC POWER SOURCE δ ...
Страница 2: ......
Страница 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Страница 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Страница 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Страница 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Страница 134: ...NOTES 122 NOTES ...
Страница 135: ...MODIFCATIONS 123 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made ...