19. Install a hand pump with an accurate 0-2,000 psi (0-
13,800 kPa) gauge and shut-off valve to the brake
release port. Apply 1,000 psi (6,900 kPa) to the brake
and close the shut-off valve. Let the brake stand for
five (5) minutes. If there is any loss of pressure, the
brake pack should be disassembled for inspection of
the sealing surfaces and the brake piston. Release
the pressure, remove the hand pump and install the
brake release tube (43) between the brake valve
block (39) and the brake release port.