4.Advanced User Guidebook
75
FFR
: Time between Source A first falling edge and Source B first rising edge.
FFF
: Time between Source A first falling edge and Source B first falling edge.
LRR
: Time between Source A first rising edge and Source B last rising edge.
LRF
: Time between Source A first rising edge and Source B last falling edge.
LFR
: Time between Source A first falling edge and Source B last rising edge.
LFF
: Time between Source A first falling edge and Source B last falling edge.
Other measurements
+PulseCount
: The number of positive pulses that rise above the
mid reference crossing in the waveform.
-PulseCount
: The number of negative pulses that fall below the
mid reference crossing in the waveform.
RiseEdgeCnt
: The number of positive transitions from the low
reference value to the high reference value in the waveform.
FallEdgeCnt
: The number of negative transitions from the high
reference value to the low reference value in the waveform.
Area
: The area of the whole waveform within the screen and the
unit is voltage-second. The area measured above the zero reference
(namely the vertical offset) is positive; the area measured below the zero
reference is negative. The area measured is the algebraic sum of the area
of the whole waveform within the screen.
Cycle Area
: The area of the first period of waveform on the screen
and the unit is voltage-second. The area above the zero reference (namely
the vertical offset) is positive and the area below the zero reference is
negative. The area measured is the algebraic sum of the area of the whole
period waveform.
Note: When the waveform on the screen is less than a period, the period
area measured is 0.
Customize an Automatic Measurement
You can customize automatic measurements by using gating and statistics.
Gating
Press the
Measure
button, and the automatic measurement function menu
is displayed at the bottom of the screen;
Press the
Set
softkey at the bottom of the screen, the setting menu
appears on the right side of the screen;
Select the
Gating
menu. There are two menus:
Screen
and
Cursor
under
the range. Click the
Screen
and then click the
Cursor
, or press the right
Содержание TAO3000 Dual-Channel Series
Страница 1: ...TAO3000 Dual Channel Series Tablet Oscilloscopes User Manual www owon com ...
Страница 93: ...4 Advanced User Guidebook 87 Figure 4 24 Hamming window Figure 4 25 Rectangle window ...
Страница 94: ...4 Advanced User Guidebook 88 Figure 4 26 Blackman window Figure 4 27 Hanning window ...
Страница 95: ...4 Advanced User Guidebook 89 Figure 4 28 Kaiser window Figure 4 29 Bartlett window ...