Take Readings
Remove the patch cable from the detector port on the WaveTester, and bring both units to the opposite ends of the link
under test.
Be careful to ensure that you do NOT remove the patch cable from the WaveSource.
Connect the WaveTester and WaveSource to the link under test as shown in Figure 3 below.
Press
on the WaveTester to store readings for both 1310nm and 1550nm simultaneously for the current fiber under
test.
The fiber number on the WaveTester will increment by 2.
Disconnect the patch cables from both ends of the patch panel and move to the next port on the patch panel.
Repeat steps
and
for each fiber in the cable under test until all fibers have been tested.
(end of procedure)
SAVE
26
QUICK REFERENCE GUIDES
Optical Power Meter:
WAVETESTER
Fiber Optic Light Source:
WAVESOURCE Series Singlemode Sources
PAGE 3 OF 3
FIGURE 3
Taking
Readings
LIGHT SOURCE CONNECTOR
PORT NOTES:
– CONNECTOR TYPE MAY VARY
– DO NOT INSERT ANGLED
PHYSICAL CONTACT (APC)
CONNECTOR
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
dB
2.00
-
1310
nm
SC connectors shown here;
connector style may vary