QUICK REFERENCE GUIDES
Required Accessories
(2-3) one-meter patch cables – ensure proper connector type and fiber type
if you are testing at both 1310nm and 1550nm, each light source wavelength will require its own patch
cable.
Equipment Ports
Figure 1 shows the ports used during this procedure. These ports may vary depending upon the model of equipment.
Verify Proper Operation of the Equipment
Connect the power meter and light source together with the first patch cable as shown in Figure 2.
Press
to power on the Laser OWL singlemode laser source. The 1310nm port powers on first by default.
Press
to power on the WaveTester optical power meter.
Detector
WaveTester power meter
FIGURE 1
Test Equipment Ports
(connector port on
light source may vary)
21
Optical Power Meter:
WAVETESTER
Fiber Optic Light Source:
LASER OWL Series Singlemode Sources
PAGE 1 OF 3
1310 nm
1550 nm
Laser OWL singlemode
laser source
FIGURE 2
Verify
Patch
Cable
SC connectors shown here;
connector style may vary
LIGHT SOURCE CONNECTOR
PORT NOTES:
– CONNECTOR TYPE MAY VARY
– DO NOT INSERT ANGLED
PHYSICAL CONTACT (APC)
CONNECTOR