background image

5

Valves, co systems

Three-way mixing valve “Tri-M TR”

Installation and operating instructions for the specialised installer

EN

Subject to technical modifications without notice.

For an overview or our global presence 

visit www.oventrop.com.

PRECAUTION

!

PRECAUTION indicates a possible dangerous 

situation which may lead to minor or moderate injury 

if the safety guidelines are not observed.

DANGER

!

DANGER indicates an imminent dangerous situation 

which will lead to death or serious injury if the safety 

guidelines are not observed.

WARNING 

!

WARNING indicates a possible dangerous situation 

which may lead to death or serious injury if the safety 

guidelines are not observed.

1  General information

1.1    Information regarding installation and 

operating instructions

These installation and operating instructions serve the 
installer to install the valve professionally and to put it 
into operation.
Other valid documents – manuals of all system 
components as well as valid technical rules – must be 
observed. 

1.2  Keeping of documents

The installation and operating instructions should be 
kept by the user of the system for later reference.

1.3 Copyright

The installation and operating instructions are 
copyrighted.

1.4  Symbol explanation

Safety guidelines are displayed by symbols. These 
guidelines are to be observed to avoid accidents, 
damage to property and malfunctions. 

!

Read installation and operating instructions in their 

entirety before installing the valve!

Installation, initial operation, operation and 

maintenance must only be carried out by qualified 

tradesmen!

The installation and operating instructions, as well 

as other valid documents must remain with the 

user of the system!

Content

1  General information. . . . . . . . . . . . . . . . . . . . . . 5
2  Safety notes  . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3  Transport, storage and packaging  . . . . . . . . . . 6
4  Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . 6
5  Construction and function. . . . . . . . . . . . . . . . . 7
6 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8 Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 
9  General conditions of sales and delivery  . . . . . 8

Illustr. 1.1 Three-way mixing valve “Tri-M TR” 

Содержание Tri-M TR

Страница 1: ...iese Einbau und Betriebsanleitung dient dem ges chulten Fachpersonal dazu das Ventil fachgerecht zu installieren und in Betrieb zu nehmen Mitgeltende Unterlagen Anleitungen aller Anlagen komponenten s...

Страница 2: ...Medium Nicht aggressive Fl ssigkeiten z B Was ser und geeignete Wasser Glykolgemische gem VDI 2035 Nicht f r Dampf lhaltige und aggressive Me dien geeignet WARNUNG Schweres Ventil Verletzungsgefahr G...

Страница 3: ...ndruck A B AB Anschl sse 6 Einbau Oventrop Tri M TR Dreiwege Mischventile werden mit berwurfmuttern zum Anschluss von Schwei t l len aus Stahl bzw L t oder Gewindet llen aus Mes sing ausgeliefert Die...

Страница 4: ...rtung und Pflege Die Armatur ist wartungsfrei Die Dichtheit und Funktion der Armatur und ihrer Ver bindungsstellen ist im Rahmen der Anlagenwartung regelm ig zu berpr fen Eine gute Zug nglichkeit der...

Страница 5: ...ut it into operation Other valid documents manuals of all system components as well as valid technical rules must be observed 1 2 Keeping of documents The installation and operating instructions shoul...

Страница 6: ...0 750 mbar DN 25 500 mbar DN 40 200 mbar Tight closing in final position of the valve disc Fluids Non aggressive harmless fluids e g water and suitable water and glycol mixtures according to VDI 2035...

Страница 7: ...onnections 6 Installation Oventrop three way mixing valves Tri M TR are supplied with collar nuts for the connection of weldable tailpipes made of steel or solder or screwed tailpipes made of brass Th...

Страница 8: ...es can be found in the catalogue 8 Maintenance The three way mixing valve is maintenance free Tightness and function of the valve and its connection points have to be checked regularly during maintena...

Страница 9: ...ord selon les r gles de l art Les autres documents de r f rence les notices de tous les composants du syst me ainsi que les r gles techniques en vigueur sont respecter 1 2 Conservation des documents C...

Страница 10: ...du clapet Fluides compatibles Fluides non agressifs par ex eau et m langes eau glycol ad quats selon VDI 2035 Ne convient pas la vapeur ni aux fluides huileux et agressifs AVERTISSEMENT Robinet lourd...

Страница 11: ...s OV Oventrop DN Dimension nominal PN Pression nominale A B AB Raccordements 6 Montage Les robinets mitigeurs trois voies Oventrop Tri M TR sont livr s avec des crous d accouplement pour le raccordeme...

Страница 12: ...ogue 8 Entretien Le robinet ne n cessite aucun entretien Le fonctionnement du robinet et l tanch it des points de raccordement doivent tre v rifi s r guli rement lors de l entretien de l installation...

Страница 13: ...handleidingen van alle installatiecomponenten en geldende technische voorschriften moet eveneens in acht genomen worden 1 2 Documentatie bewaren Deze installatie en bedieningshandleiding moet door de...

Страница 14: ...s volgens VDI 2035 Niet geschikt voor stoom oliehoudende en agressieve media WAARSCHUWING Zware mengkraan Gevaar voor verwondingen Gebruik uitsluitend geschikte transport en hefinrichtingen Draag tijd...

Страница 15: ...orlaat PN Nominale druk A B AB Aansluitingen 6 Montage Oventrop Tri M TR 3 weg mengkranen worden met wartels voor de aansluiting van stalen lasmoffen of van messing soldeer of draadmoffen geleverd Voo...

Страница 16: ...e 8 Onderhoud De appendage is onderhoudsvrij In het kader van onderhoud aan de installatie moet de appendage regelmatig op dichtheid en werking worden gecontroleerd Het is raadzaam om ervoor te zorgen...

Отзывы: