background image

6

2  Safety notes

2.1  Correct use

Safety in operation is only guaranteed if the valve is 

used correctly.

The three-way mixing valve “Tri-M TR” is used for 

mixing or changing-over of volume flows in heating 

and cooling systems.

Any use of the valve outside the above applications 

will be considered as non-compliant and misuse. 

Claims of any kind against the manufacturer and/or 

his authorised representatives due to damages caused 

by incorrect use cannot be accepted.

The observance of the installation and operating 

instructions is part of the compliance terms.
 

2.2   Possible dangers at the installation location 

and during transport 

The case of an external fire has not been taken into 

consideration when constructing the valve.

3.2  Storage

The three-way valve must only be stored under the 

following conditions:

–   Do not store in open air, keep dry and free from dust.

–   Do not expose to aggressive fluids or heat sources.

–   Protect from direct sunlight and mechanical agitation.

–  Storage temperature: –20 °C up to +60 °C

–  Max. relative humidity of air: 95 %

3.3  Packaging

Packaging material is to be disposed of in an 

environmentally friendly manner.

4  Technical data

4.1  Performance data

Max. operating temperature t

s

:   +120°C, for short 

periods up to +130°C

Min. operating temperature t

s

: 0°C

Max. operating pressure p

s

1600 kPa (16 bar)

Permissible pressure

difference Δp

max

.:  

DN 20: 750 mbar

  

   

DN 25: 500 mbar

  

   

DN 40: 200 mbar 

Tight closing in final position of the valve disc.

Fluids:

 Non aggressive, harmless fluids (e.g. water 

and suitable water and glycol mixtures according to 

VDI 2035). Not suitable for steam, oily and aggressive 

fluids.

   WARNING 

!

Heavy valve!

Risk of injury! 

Suitable transport and lifting devices 

are to be used. Wear suitable protective clothing (e.g. 

safety shoes) during installation and use safety devices. 

External components like handwheels must not be 

misused for the absorption of external forces, e.g. 

as carrying handle or connection point for lever tools 

etc. 

Hot or cold surfaces!

Risk of injury! 

Do not touch without safety gloves. 

The valve may get very hot or cold during operation.

Sharp edges!

Risk of injury! 

Only touch with safety gloves. Threads, 

bore holes and edges are sharp. 

Small components!

Risk of ingestion! 

Store and install the valve out of 

reach of children.

Allergies!

Health hazard! 

Do not touch the valve and avoid any 

contact if allergies against the used materials are 

known.

DANGER

!

Suitable measures (e.g. safety valves) have to be 

taken to ensure that the maximum operating 

pressures and the maximum and minimum operating 

temperatures are not exceeded or undercut.

4.2 Materials

Valve body made of corrosion resistant bronze, inner 

parts made of brass and stainless steel, seals of the 

valve insert made of EPDM.

3   Transport, storage and 

packaging

3.1  Transport inspection

Upon receipt check delivery for any damages caused 

during transit and for completeness.

Any damage must be reported immediately upon 

receipt.

Содержание Tri-M TR

Страница 1: ...iese Einbau und Betriebsanleitung dient dem ges chulten Fachpersonal dazu das Ventil fachgerecht zu installieren und in Betrieb zu nehmen Mitgeltende Unterlagen Anleitungen aller Anlagen komponenten s...

Страница 2: ...Medium Nicht aggressive Fl ssigkeiten z B Was ser und geeignete Wasser Glykolgemische gem VDI 2035 Nicht f r Dampf lhaltige und aggressive Me dien geeignet WARNUNG Schweres Ventil Verletzungsgefahr G...

Страница 3: ...ndruck A B AB Anschl sse 6 Einbau Oventrop Tri M TR Dreiwege Mischventile werden mit berwurfmuttern zum Anschluss von Schwei t l len aus Stahl bzw L t oder Gewindet llen aus Mes sing ausgeliefert Die...

Страница 4: ...rtung und Pflege Die Armatur ist wartungsfrei Die Dichtheit und Funktion der Armatur und ihrer Ver bindungsstellen ist im Rahmen der Anlagenwartung regelm ig zu berpr fen Eine gute Zug nglichkeit der...

Страница 5: ...ut it into operation Other valid documents manuals of all system components as well as valid technical rules must be observed 1 2 Keeping of documents The installation and operating instructions shoul...

Страница 6: ...0 750 mbar DN 25 500 mbar DN 40 200 mbar Tight closing in final position of the valve disc Fluids Non aggressive harmless fluids e g water and suitable water and glycol mixtures according to VDI 2035...

Страница 7: ...onnections 6 Installation Oventrop three way mixing valves Tri M TR are supplied with collar nuts for the connection of weldable tailpipes made of steel or solder or screwed tailpipes made of brass Th...

Страница 8: ...es can be found in the catalogue 8 Maintenance The three way mixing valve is maintenance free Tightness and function of the valve and its connection points have to be checked regularly during maintena...

Страница 9: ...ord selon les r gles de l art Les autres documents de r f rence les notices de tous les composants du syst me ainsi que les r gles techniques en vigueur sont respecter 1 2 Conservation des documents C...

Страница 10: ...du clapet Fluides compatibles Fluides non agressifs par ex eau et m langes eau glycol ad quats selon VDI 2035 Ne convient pas la vapeur ni aux fluides huileux et agressifs AVERTISSEMENT Robinet lourd...

Страница 11: ...s OV Oventrop DN Dimension nominal PN Pression nominale A B AB Raccordements 6 Montage Les robinets mitigeurs trois voies Oventrop Tri M TR sont livr s avec des crous d accouplement pour le raccordeme...

Страница 12: ...ogue 8 Entretien Le robinet ne n cessite aucun entretien Le fonctionnement du robinet et l tanch it des points de raccordement doivent tre v rifi s r guli rement lors de l entretien de l installation...

Страница 13: ...handleidingen van alle installatiecomponenten en geldende technische voorschriften moet eveneens in acht genomen worden 1 2 Documentatie bewaren Deze installatie en bedieningshandleiding moet door de...

Страница 14: ...s volgens VDI 2035 Niet geschikt voor stoom oliehoudende en agressieve media WAARSCHUWING Zware mengkraan Gevaar voor verwondingen Gebruik uitsluitend geschikte transport en hefinrichtingen Draag tijd...

Страница 15: ...orlaat PN Nominale druk A B AB Aansluitingen 6 Montage Oventrop Tri M TR 3 weg mengkranen worden met wartels voor de aansluiting van stalen lasmoffen of van messing soldeer of draadmoffen geleverd Voo...

Страница 16: ...e 8 Onderhoud De appendage is onderhoudsvrij In het kader van onderhoud aan de installatie moet de appendage regelmatig op dichtheid en werking worden gecontroleerd Het is raadzaam om ervoor te zorgen...

Отзывы: