![Oval EX DELTA, EX DELTA-DIA Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/oval/ex-delta-ex-delta-dia/ex-delta-ex-delta-dia_manual_1662162056.webp)
56
D-546-9-E
17. PRODUCT CODE EXPLANATION
17.1 Battery Powered EX Delta
Table 17.1
Item
Product Code
Description
① ② ③ ④ ⑤ ⑥ ⑦ - ⑧ ⑨ ⑩ ⑪ - ⑫ ⑬ ⑭ ⑮
Model V X
EX DELTA
Body Style
W
Wafer type (Nom. sizes: 10 to 150mm)
Fixed sensor type
F
Flanged type (Nom. sizes: 40 to 300mm) RF is Std.
R
Flanged type (Nom. sizes: 40 to 300mm) RF is Std.
Replaceable sensor type
Application
1
Standard (Delta shaped vortex shedding bluff body)
Nominal Bore Size
0 1 0 -
10mm (Liquids only)
0 1 5 -
15mm
0 2 5 -
25mm
0 4 0 -
40mm
0 5 0 -
50mm
0 8 0 -
80mm
1 0 0 -
100mm
1 5 0 -
150mm
2 0 0 -
200mm
2 5 0 -
250mm
3 0 0 -
300mm
Major Parts Material
N
SCS14A (Nominal sizes 10 to 150mm)
SUS316 (Nominal sizes 200 to 300mm)
C
SFVC2A (Nominal sizes 200 to 300mm)
See Note 1.
Z
Special (other than above)
Flange Rating
1
JIS 10K
2
JIS 16K
3
JIS 20K
4
JIS 30K
5
ASME 150
See Note 2.
6
ASME 300
See Note 2.
7
JPI 150
8
JPI 300
A
DIN PN 10
See Note 3.
B
DIN PN 16
See Note 3.
C
DIN PN 25
See Note 3.
D
DIN PN 40
See Note 3.
9
Others
Sensor Construction
1
Standard
2
Separate sensor probe type
Fluids to be Metered
G -
Gas, Steam (<300℃)
L -
Liquid (<300℃)
S -
High temp. application for gas, steam (over 300℃ and <460℃)
See Note 4.
H -
High temp. application for liquid (over 300℃ and <460℃)
See Note 4.
Converter Construction
1
Integral type
2
Separate type
Explosionproof Construction
0
Nonexplosionproof
3
Intrinsic safety (TIIS)
Display
1
w/Totalizer & Digital indicator
See Note 5.
Output signal
0
Non Output (battery powered type)
Notes 1. Body material for meters 200mm to 300mm in nominal size is SUS316 pipe + SFVC2A flanges. Meters
approved to comply with high pressure gas safety requlations are not applicable, however.
2. Flange serration for ASME standard: ASME B 16.5-1996.
3. Body style for DIN is applicable to wafer type only.
4. Meter body for high temperature service is of flanged replaceable sensor type.
5. The following variables are selectable with an external switch for the display:
(1) Totalizing counter
(2) Instantaneous flowrate (/h)
(3) Instantaneous flowrate (/min)
(4) Resettable counter
Содержание EX DELTA, EX DELTA-DIA
Страница 22: ...22 D 546 9 E 7 3 Separate mount Preamp to Probe Terminal Box Wiring Diagram...
Страница 36: ...36 D 546 9 E 11 3 Preamplifier Block Diagrams...
Страница 39: ...39 D 546 9 E 14 EXPLODEDED VIEW AND PARTS LIST 14 1 Fixed Sensor NOTE Parts list on the next page...
Страница 41: ...41 D 546 9 E 14 2 Replaceable Sensor Type NOTE See next page for parts list...
Страница 58: ...D 546 9 E All speci cations are subject to change without notice for improvement 2011 11 Revised D 546 9 E 1...