13. ABOUT ERROR MESSAGES
Parameters may be changed as you choose in this flow computer, but if inconsistent, conflicting parameters
are entered, or when faulty conditions take place, the preamplifier LCD display will tell the operator with error
messages as shown in Table 13.1 below.
Message
Name
Description
Remedy
PA. Err.
Parameter setup
error
An attempt is made to rewrite
a parameter while parameters
are write-protected.
(In the standard model, write-
protect feature is set in OFF
and will not appear.)
Can be reset by placing No.1
of display board SW1 in OFF.
(This enables you to change
parameters.)
PA. Err. 1
Parameter error 1
Backup data retained for
parameters has been
damaged.
CPU initialization and then
reconfiguration of
parameters are required.
PA. Err. 2
Parameter error 2
Some of the backup data
retained for the display mode,
grand total flow reading, or
resettable total flow reading
have been damaged.
Measure mode can be
restored with MODE switch,
but the grand total flow and
resettable total reading will
be reset to 0.
PA. Err. Pu
Pulse weight error Pulse weight “Pu” setting is
too small with respect to
meter factor “F” and
conversion factor “H.”
Change the setting to an
appropriate value that the
relationship between F, H,
and Pu satisfies the following
formula:
F×H
2 ≦Pu≦F×H×10000
“
”
(BA TT mark comes on.)
Battery life
Supply voltage has dropped.
Replace the battery with a
new one.
● Procedure to initialize the CPU
① Turn POWER switch OFF.
② Holding the internal MODE switch (Do not be confused with external mode select switch. See pages 10
and 33) depressed, turn POWER switch ON.
③ The LCD display is illuminated in all places. (Hold MODE switch depressed.)
④ On seeing a message “PA. rESEt,” release the MODE switch (initialization is complete).
(Holding the MODE switch ON at this point while a message “PA.rESEt” appears will result in unsuccessful
initialization.)
NOTES:
1. Following the initialization, reestablishing the parameters is required.
2. Except for seeing a message “PA. Err. 1” (parameter error 1), do not perform initialization
procedure.
➡
➡
Содержание EX DELTA, EX DELTA-DIA
Страница 22: ...22 D 546 9 E 7 3 Separate mount Preamp to Probe Terminal Box Wiring Diagram...
Страница 36: ...36 D 546 9 E 11 3 Preamplifier Block Diagrams...
Страница 39: ...39 D 546 9 E 14 EXPLODEDED VIEW AND PARTS LIST 14 1 Fixed Sensor NOTE Parts list on the next page...
Страница 41: ...41 D 546 9 E 14 2 Replaceable Sensor Type NOTE See next page for parts list...
Страница 58: ...D 546 9 E All speci cations are subject to change without notice for improvement 2011 11 Revised D 546 9 E 1...