6.5 How to Change Preamplifier (Totalizer) Display Orientation
The display (totalizer) can be rotated to the desired
direction in 90° steps through 360°. By changing the
angle of display board (internal assembly), the
totalizer display appears for maximum readability on
a vertical run or a horizontal run.
〈How to Change Display Angle〉
Refer to Sec. 13, “EXPLODED VIEW AND PARTS LIST”
on pages 38 and 41.
① Remove the window cover (Fig. 6.10).
② Turn off the “POWER” switch on the display board
(Fig. 6.11).
③ Take off four screws holding the display board
(Fig. 6.12).
NOTE:
The procedure above applies to the
separate-mount type preamplifier.
④ Separate the display board from the preamplifier
body (Fig. 6.12).
⑤ Orient the display board to the desired angle and
secure the display board with four screws
(adjustable in 90° steps).
CAUTION: Never make a mistake in coupling
the connector with its receptacle.
⑥ Turn on the “POWER” switch on the display
board.
⑦ Install the window cover in place.
IMPORTANT: Screw in the cover as far as it will
go to ensure tight installation.
➡
➡
Horizontal Run
Vertical Run
Windowed
Cover
“POWER”Switch
ON
OFF
Display Board
Rotatable
in 90°steps
Display Board
Connectors
Содержание EX DELTA, EX DELTA-DIA
Страница 22: ...22 D 546 9 E 7 3 Separate mount Preamp to Probe Terminal Box Wiring Diagram...
Страница 36: ...36 D 546 9 E 11 3 Preamplifier Block Diagrams...
Страница 39: ...39 D 546 9 E 14 EXPLODEDED VIEW AND PARTS LIST 14 1 Fixed Sensor NOTE Parts list on the next page...
Страница 41: ...41 D 546 9 E 14 2 Replaceable Sensor Type NOTE See next page for parts list...
Страница 58: ...D 546 9 E All speci cations are subject to change without notice for improvement 2011 11 Revised D 546 9 E 1...