43
D-546-9-E
15. GENERAL SPECIFICATIONS
15.1 Sensor Specifications
15.1.1 EX Delta Sensor Specifications
Tabele 15.1
Item
Description
Sensor type
Fixed sensor
Fixed sensor
Replaceable sensor
Nominal size (mm)
10, 15, 25, 40, 50, 80, 100, 150 40, 50, 80, 100, 150, 200, 250, 300 40, 50, 80, 100, 150, 200, 250, 300
Body style
Wafer type
Flanged type (RF is standard.) Flanged type (RF is standard.)
Flange rating
JIS 10, 16, 20, 30K ASME/JPI 150, 300
DIN PN10, 16, 25, 40
JIS 10, 16, 20, 30K ASME/JPI 150, 300
Std. connecting pipe
Nominal wall thickness Sch 40 *1
Applicable fluid
Liquids, gases and steam *2
Operating temp. range
*3
-30 to +300℃
Nominal size 200~300mm with flange material SFVC2A…0 to 300℃
(Temp. limitation depends on the flange material used.)
Standard type :-30 to +300℃
High temp. type : -30 to +460℃
However, min. temp. for nom.
size, 200 to 300mm is specified
as 0°due to limitation in
material component.
Max. operating pressure
Depends on flange rating (Design pressure: 5.00MPa).
Accuracy
Select one from the following two ranges according to the given operating conditions:
1: ±1% of indicated reading or better 2: ±1% of full scale or better *4
Repeatability
±0.2% or better
Materials
Body
SCS14A
Nom. size 10mm・・・SUS316
SUS316 or SCS14A
(Nom. size 200 to 300mm…Flange material is SUS316 or SFVC2A.)
Bluff body
(delta or dia. shaped)
SUS316 or SCS14A
Adapter
SUS304 or SCS13A
Installation
No restrictions to cause loss of accuracy on physical orientation
Maintainability and waterproof work for cable entry should be taken into consideration.
Finish (measuring pipe)
Nominal sizes 10 to 300mm: Remains unfinished (because of stainless steel material)
Nominal sizes 200 to 300mm: Phthalate resin finished Munsell 2.5G8/2 (SFVC2A only)
(*1): If different from piping of standard nominal wall thickness, consult the factory. (*2): 10mm is dedicated for liquid measurement only.
(*3): With nominal size 200 to 300mm. and flange material SFVC2A, the allowable operating temperature covers a range above 0℃ due to
temperature limitations by flange material.
(*4): Accuracy of 10mm in nom. size is ±2% or better with respect to the max. rated flowrate.
● Flange Ratings and Maximum Operating Pressures
Nominal Dia. 10 to 300mm (Material: SUS316 or SCS14A)
Unit: MPa
Nominal Dia. 200 to 300mm (Material:SFVC2A)
Unit: MPa
Flange Rating
Operating Temperature
JIS 10K
JIS 16K
JIS 20K
JIS 30K
ASME 150
ASME 300
Below 220℃
1.18
2.45
3.04
4.51
1.32
4,31
Above 220℃ to 300℃
0.98
2.26
2.84
4.22
1.02
3.87
Above 300℃ to 350℃
――
2.06
2.55
3.82
0.84
3.70
Above 350℃ to 420℃
――
1.57
1.96
2.94
0.56
2.88
NOTE: See meter tag or approval drawing for the operating flow ranges and operating temp. ranges and
preamplifier output specifications.
➡
➡
Flange Rating
Operating Temp.
JIS 10K JIS 16K JIS 20K JIS 30K
ASME/
JPI 150
ASME/
JPI 300
DIN
PN10
DIN
PN16
DIN
PN25
DIN
PN40
Below 220°C
1.18
1.96
2.45
4.51
1.27
3.35
0.62
1.00
1.78
2.50
Above 220 to 300°C
0.98
1.77
2.26
4.22
1.02
3.06
0.56
0.90
1.61
2.26
Above 300 to 350°C
─
1.57
1.96
3.82
0.84
2.96
─
─
─
─
Above 350 to 420°C
─
─
─
2.94
0.57
2.81
─
─
─
─
Above 420 to 460°C
─
─
─
─
0.42
2.71
─
─
─
─
Содержание EX DELTA, EX DELTA-DIA
Страница 22: ...22 D 546 9 E 7 3 Separate mount Preamp to Probe Terminal Box Wiring Diagram...
Страница 36: ...36 D 546 9 E 11 3 Preamplifier Block Diagrams...
Страница 39: ...39 D 546 9 E 14 EXPLODEDED VIEW AND PARTS LIST 14 1 Fixed Sensor NOTE Parts list on the next page...
Страница 41: ...41 D 546 9 E 14 2 Replaceable Sensor Type NOTE See next page for parts list...
Страница 58: ...D 546 9 E All speci cations are subject to change without notice for improvement 2011 11 Revised D 546 9 E 1...