5
D-546-9-E
17.2 Battery Powered EX Delta Dia
Table 17.2
Item
Product Code
Description
① ② ③ ④ ⑤ ⑥ ⑦ - ⑧ ⑨ ⑩ ⑪ - ⑫ ⑬ ⑭ ⑮
Model V X
EX DELTA
Body style
W
Wafer type (Nominal sizes: 15 to 80mm)
Fixed sensor type
See Note 3.
F
Flanged type (sizes: 50, 80mm) RF is std.
R
Flanged type (sizes: 50, 80mm) RF is std.
Replaceable sensor type
Application
2
Diamond shaped bluff body
Nominal size
0 1 5
15mm
0 2 5
25mm
0 4 0
40mm
0 5 0
50mm
0 8 0
80mm
-
Material
N
SCS14A (Nominal sizes 15, 25 wafer type)
C
SUS316
Z
Special (other than above)
Flange rating
1
JIS 10K
2
JIS 16K
3
JIS 20K
4
JIS 30K
5
ASME 150
See Note 1.
6
ASME 300
See Note 1.
7
JPI 150
8
JPI 300
9
Other
Sensor construction
2
Separate sensor type
Applicable fluid
L
Liquid
H
High temp. application for liquid (Over 300℃ and <460℃) (flanged
type replaceable sensor)
-
Converter construction
1
Integral type
2
Separate type
Explosionproof construction
0
Nonexplosionproof
3
Intrinsic safety (TIIS)
Display
1
w/Totalizer & Digital indicator
See Note 2.
Output signal
0 Non Output (battery powered type)
Notes 1. Flange serration for ASME standard: ASME B 16.5-1996.
2. The following variables are selectable with an external switch for the display:
(1) Totalizing counter
(2) Instantaneous flowrate (/h)
(3) Instantaneous flowrate (/min)
(4) Resettable counter
3. Applicable item.
Nominal size (mm)
15
25
40
50
80
Wafer type
○
○
○
○
○
Flanged type
-
-
-
○
○
○:Standard -:Option
Содержание EX DELTA, EX DELTA-DIA
Страница 22: ...22 D 546 9 E 7 3 Separate mount Preamp to Probe Terminal Box Wiring Diagram...
Страница 36: ...36 D 546 9 E 11 3 Preamplifier Block Diagrams...
Страница 39: ...39 D 546 9 E 14 EXPLODEDED VIEW AND PARTS LIST 14 1 Fixed Sensor NOTE Parts list on the next page...
Страница 41: ...41 D 546 9 E 14 2 Replaceable Sensor Type NOTE See next page for parts list...
Страница 58: ...D 546 9 E All speci cations are subject to change without notice for improvement 2011 11 Revised D 546 9 E 1...