PRO208V-5k75 Installation and Safety Manual
900-0203-01-00 Rev B
17
(b)
Connect power to the Gateway using the
appropriate AC cable (Figure 13). Ethernet
may also be connected at this stage.
(c)
Turn on power to the inverter.
On the Gateway screen, select the
Inverters
tab
A
at the top of the screen
if the unit is not already on that tab.
Press <
Setup
>, then the <
Discover
>
button
B
.
The Gateway will search for all
inverters. Confirm that they indicate
Healthy
status as shown in
C
.
4.
Connect the strings of PV modules.
This may be done with the AC source on or off.
This section assumes the source is off.
Do not reverse the polarity of the DC
inputs. This will cause irreparable damage
to the ProHarvest inverter.
All connectors must be fully mated to
ensure weatherproofing.
Use the DC tool to disconnect the male and
female connectors. Follow steps
1
and
2
in the
Disconnection section of Figure 15.
With the AC off but PV voltage present, the
inverter button will flash red and emit a short
audible beep, indicating a fault. (See Table 2
on page 20.) This is normal when utility grid is
not present.
A
C
B
Connection
Disconnection
1
2
Figure 13: Making Gateway connections
Figure 14: Having the Gateway auto-discover added inverters
Figure 15: Connecting and disconnecting MC4-compatible module connectors
AC Connection
Ethernet
Connection
(optional)